Percutaneous balloon aortic valvuloplasty. Acute and 30-day follow-up results in 674 patients from the NHLBI Balloon Valvuloplasty Registry.
- 1 December 1991
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 84 (6) , 2383-2397
- https://doi.org/10.1161/01.cir.84.6.2383
Abstract
BACKGROUND Percutaneous balloon aortic valvuloplasty has been used as a therapeutic option for relief of valvular stenosis. This study describes patients undergoing initial percutaneous aortic balloon valvuloplasty enrolled in the National Heart, Lung, and Blood Institute (NHLBI) Balloon Valvuloplasty Registry. METHODS AND RESULTS Extensive baseline procedural and postprocedural data were tabulated in 674 patients during a 24-month period. Functional status was captured using standard methods and an overall functional scoring system. Complications were defined and divided into procedural, acute (within 24 hours), in-hospital, and within 30 days of the procedure. The patient population was elderly and symptomatic, with 83% greater than 70 years of age. New York Heart Association functional class (FC) III or IV congestive heart failure (CHF) was present in 76%, syncope or presyncope was present in 34%, and Canadian Heart Association class III or IV angina was present in 23%. Using an overall functional scoring system (0-100), 54% exhibited scores less than 50. Comorbid disease was common. Forty-five percent possessed at least one serious noncardiac disability as a reason for valvuloplasty. Eighty percent of those seen by a cardiothoracic surgeon were believed inappropriate for aortic valve replacement. Hemodynamically, the aortic valve area increased from 0.5 +/- 0.2 cm2 to 0.8 +/- 0.3 cm2 (p less than 0.0001), accompanied by a fall in mean and peak aortic valve gradient from 55 +/- 21 and 65 +/- 28 mm Hg to 29 +/- 13 and 31 +/- 18 mm Hg, respectively (both p less than 0.0001). Small but significant increases were observed in cardiac output, heart rate, and mean aortic pressure with minor declines in the pulmonary artery (PA) systolic and left ventricular (LV) end-diastolic pressure. One hundred sixty-seven (25%) experienced at least one significant complication within 24 hours, and 211 (31%) experienced a significant complication before discharge. Complications before hospital discharge included the need for transfusion (23%), vascular surgery (7%), cerebrovascular accident (3%), other systemic embolus (2%), myocardial infarction (2%), acute tubular necrosis (1%), or cardiac surgery (1%). Seventeen (3%) patients died during the procedure; 16 of those were due to cardiac causes. By hospital discharge, there was an additional 52 total deaths; 37 were due to cardiovascular causes. Between hospital discharge and 30 days, 23 additional deaths occurred; 18 were due to cardiac disease. At 30 days, therefore, there was a grand total of 92 (14%) deaths; 71 (11%) were due to cardiovascular-related causes. Univariate and logistic regression analysis of mortality revealed that death was most frequent in patients suffering multiorgan failure and poor LV systolic function. Thirty-day mortality was associated with a predefined high-risk subset of hypotension and NYHA class IV CHF (risk ratio, 4.4), blood urea nitrogen (BUN) greater than 30 mg/dl (risk ratio, 3.7), use of an antiarrhythmic (risk ratio, 2.9), and cardiac output less than 3.0 l/min (risk ratio, 2.4). Of the survivors (86%) at 30 days, symptomatic improvement was generally present. Seventy-five percent experienced at least one functional class improvement in CHF, and 53% experienced at least a quartile improvement in overall functional status score. CONCLUSIONS These data reveal that percutaneous aortic balloon valvuloplasty in an elderly and debilitated population can be done with low mortality but substantial morbidity. Mortality is greatest in patients with multiorgan failure resulting from poor cardiac output. In patients with reasonably preserved LV function who are otherwise inappropriate surgical candidates because of comorbid factors, survival and early improvement in symptomatic status are frequently observed after percutaneous aortic valvuloplasty.Keywords
This publication has 86 references indexed in Scilit:
- Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. IPublished by Elsevier ,2004
- Results of percutaneous valvuloplasty for calcific aortic stenosis with different balloon cathetersCatheterization and Cardiovascular Diagnosis, 1989
- Utility of Doppler color flow imaging for identification of femoral arterial complications of cardiac catheterizationAmerican Heart Journal, 1989
- Analysis of the early rise in aortic transvalvular gradient after aortic valvuloplastyAmerican Heart Journal, 1989
- Comparison of three techniques for percutaneous balloon aortic valvuloplasty of aortic stenosis in adultsAmerican Heart Journal, 1989
- Aortic Valvuloplasty — A Valid Alternative?New England Journal of Medicine, 1988
- Balloon Aortic Valvuloplasty in 170 Consecutive PatientsNew England Journal of Medicine, 1988
- Bacterial endocarditis after percutaneous aortic valvuloplastyAmerican Heart Journal, 1988
- Combined percutaneous aortic valvuloplasty and coronary angioplastyAmerican Heart Journal, 1988
- Trefoil balloon for aortic valvuloplasty.Heart, 1986