The Vapor Pressures and Critical Constants of Pure Ozone
- 1 July 1952
- journal article
- research article
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 20 (7) , 1158-1161
- https://doi.org/10.1063/1.1700683
Abstract
Vapor pressures of pure ozone have been measured over the range −183°C to −30°C with an estimated accuracy of ±3 percent and are represented by the equation The normal boiling point is −111.9°C±0.3°C. The critical temperature has been determined experimentally and found to be −12.1°C±0.1°C. The critical pressure derived from this critical temperature and the vapor pressure equation is 54.6 atmospheres absolute. Results are, in general, in good agreement with the meager data in the literature. The precision of the vapor pressure data is limited by the unstable nature of ozone and the necessarily small samples which must be used for measurements in the interests in the interests of safety.
Keywords
This publication has 4 references indexed in Scilit:
- Calibration of thermocouples at low temperaturesJournal of Research of the National Bureau of Standards, 1940
- Sur l'identité des propriétés de l'ozone produit par divers modes d'effluvation de l'oxygène; point d'ébullition de l'ozone purHelvetica Chimica Acta, 1933
- Die physikalischen Konstanten des OzonsThe European Physical Journal A, 1922
- Über OzonThe Science of Nature, 1922