Doppler ultrasound estimation of microbubbles in the arterial line during extracorporeal circulation
- 1 January 1990
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 5 (1) , 23-32
- https://doi.org/10.1177/026765919000500104
Abstract
A pulsed Doppler ultrasound system was used to analyse microbubble intensity and size in the arterial line during extracorporeal circulation (ECC). Thirty male patients, younger than 70 (range 28-69) years, underwent isolated coronary artery bypass grafting with either a bubble oxygenator (Shiley S-100) without (group 1, n = 10) or with (group 2, n = 10) a depth adsorption arterial line filter (Swank High Flow 6000); or with a membrane oxygenator (Shiley M-2000) without a filter (group 3, n = 10). Mean ECC and aortic crossclamp times were similar in the three groups. Measurements were performed during the initial five minutes of cooling, after 30-40 minutes of ECC and after 10 minutes of rewarming. Microbubble intensity and size did not differ significantly in the three groups at the different intervals. Significantly more and larger bubbles were detected in group 1 (15-150μm) compared to group 2 (< 35μm) (p< 0.001). In group 3 only a minimal number of small bubbles (< 65μm) were observed. An arterial line filter significantly reduced the number and size of microbubbles detected in the arterial line during ECC. A membrane oxygenator was associated with a further reduction of microbubble intensity.Keywords
This publication has 28 references indexed in Scilit:
- The Effect of Arterial Filtration on Reduction of Gaseous Microemboli in the Middle Cerebral Artery During Cardiopulmonary BypassThe Annals of Thoracic Surgery, 1988
- Comparison of Bubble Release from Various Types of OxygenatorsScandinavian Journal of Thoracic and Cardiovascular Surgery, 1985
- Microemboli observed in deaths following cardiopulmonary bypass surgeryHuman Pathology, 1982
- Doppler Ultrasound Estimation of Bubble Removal by Various Arterial Line Filters During Extracorporeal CirculationScandinavian Journal of Thoracic and Cardiovascular Surgery, 1982
- An ultrasonic analysis of the comparative efficiency of various cardiotomy reservoirs and micropore blood filters.Thorax, 1978
- Computerized discrimination of microemboli in extracorporeal circuitsThe American Journal of Surgery, 1978
- Events Related to Microembolism during Extracorporeal Perfusion in Man: Effectiveness of In-Line Filtration Recorded by UltrasoundThe Annals of Thoracic Surgery, 1976
- Cardiopulmonary bypass. Microembolization and platelet aggregation.Circulation, 1975
- Emboli (Debris) Produced by Bubble Oxygenators Removal by FiltrationThe Annals of Thoracic Surgery, 1974
- Ultrasonic identification of sources of gaseous microemboli during open heart surgeryThorax, 1973