Clinical experience with the medpor porous polyethylene implant
- 1 January 1993
- journal article
- research article
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 17 (4) , 339-344
- https://doi.org/10.1007/bf00437109
Abstract
The Medpor porous polyethylene implant is a highly stable and somewhat flexible porous alloplast that has been shown to exhibit rapid tissue ingrowth into its pores. A total of 116 Medpor implants were placed in 70 patients over a four-year period. Implants were used for the chin, malar area, nasal reconstruction, ear reconstruction, orbital reconstruction, and the correction of craniofacial contour deformities. Many of these implants were placed in areas long considered problematic such as areas of thin soft tissue coverage, extensive scarring, and severe facial burns. Nine complications occurred including seven exposures, all of which occurred in areas of minimal soft tissue coverage. Because of the rapid vascularization of the implants, only two implants were removed, both from the columella. On the basis of our results, it is felt that the Medpor implant is an excellent alternative to existing implant materials. The implant is easy to shape; it is strong yet somewhat flexible; it is remarkably stable; and it exhibits tissue ingrowth into its pores.Keywords
This publication has 23 references indexed in Scilit:
- The Role of Alloplastic Skeletal Modification in the Reconstruction of Facial BumsAnnals of Plastic Surgery, 1993
- Reconstruction of the Burned External Ear Using a Medpor Porous Polyethylene Pivoting Helix FrameworkPlastic and Reconstructive Surgery, 1993
- CRANIOFACIAL APPLICATIONS FOR THE MEDPOR POROUS POLYETHYLENE FLEXBLOCK IMPLANTThe Journal of Craniofacial Surgery, 1992
- The Deep-Plane RhytidectomyPlastic and Reconstructive Surgery, 1990
- Evaluation of Porous Polyethylene for External Ear ReconstructionAnnals of Plastic Surgery, 1990
- Porous Hydroxyapatite as a Bone Graft Substitute in Cranial ReconstructionPlastic and Reconstructive Surgery, 1988
- Surface energies and the bone induction principleJournal of Biomedical Materials Research, 1985
- Characteristics of tissue growth into proplast and porous polyethylene implants in boneJournal of Biomedical Materials Research, 1979
- THE LONG-TERM EFFECTS OF HARD ALLOPLASTIC IMPLANTS WHEN PUT ON BONEPlastic and Reconstructive Surgery, 1976
- RETROSPECTIVE CEPHALOMETRIC ANALYSIS OF MANDIBULAR BONE ABSORPTION UNDER SILICONE RUBBER CHIN IMPLANTSPlastic and Reconstructive Surgery, 1976