Abstract
The preparation of wide bore (320 μm) and narrow bore (50 μm) fused silica capillary columns is described for immobilized cyanopropyl substituted silicones containing 60 and 88% substitution. The effect of high temperature deactivation with cyanopropylcyclosiloxanes was studied with a special test mixture. Curing was achieved with dicumyl peroxide or azo‐tert‐butane.The columns were evaluated and compared in terms of efficiency, activity, polarity, and temperature stability. Different coating methods were compared for the narrow bore columns. The activity of the 60% cyanopropyl columns that had been immobilized with dicumyl peroxide was significantly larger than for azo‐tert‐butane immobilized columns. The polarity of polar columns appeared to depend greatly on column temperature and is completely different for wide and narrow bore columns.Keywords
This publication has 18 references indexed in Scilit:
- Temperature programmed retention indices: Calculation from isothermal data. Part 1: TheoryJournal of High Resolution Chromatography, 1985
- Temperature programmed retention indices: Calculation from isothermal data. Part 2: Results with nonpolar columnsJournal of High Resolution Chromatography, 1985
- Practical aspects of fast gas chromatography on 50 μm I.D. capillary columns: combination with electron-capture detectionJournal of Chromatography A, 1984
- Fused Silica Capillary Column Technology for Gas ChromatographyJournal of Chromatographic Science, 1984
- Cyanosilicones as stationary phases in gas chromatography. I.Journal of Chromatography A, 1983
- Deactivation and coating of non-polar 50-μm I.D. capillary columnsJournal of Chromatography A, 1983
- Narrow bore open tubular columns for improvement of gas chromatographic analysis timeAnalytical Chemistry, 1983
- Azo compounds for free radical crosslinking of polysiloxane stationary phasesJournal of High Resolution Chromatography, 1983
- Increased speed of analysis in isothermal and temperature-programmed capillary gas chromatography by reduction of the column inner diameterJournal of Chromatography A, 1982
- A Static Coating Procedure for Glass Capillary ColumnsJournal of Chromatographic Science, 1968