The Effect of Partial Excision of the A2 and A4 Pulleys on the Biomechanics of Finger Flexion
- 1 February 1998
- journal article
- research article
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 23 (1) , 50-52
- https://doi.org/10.1016/s0266-7681(98)80218-0
Abstract
The purpose of this study was to investigate the effect of partial excision of the A2 and A4 pulleys on digital angular rotation and the energy required to flex the finger. Partial excision of A2 resulted in a statistically significant decrease in angular rotation of 3 and 5% after 50 and 75% excision, respectively. Partial excision of A4 failed to produce any significant differences in angular rotation. Combined partial excision of A2 and A4 resulted in a significant decrease of 5 and 8% after 50 and 75% excision, respectively. Significant differences in work of flexion occurred only after excision of 75% of the A2 pulley. Although optimal finger function relies on the integrity of the A2 and A4 pulleys which maintain the efficiency of the digital flexor system, these data suggest that 25% of the A2 pulley, up to 75% of the A4 and 25% of the A2 and A4 together can be excised without significant effects on angular rotation.Keywords
This publication has 11 references indexed in Scilit:
- Excursion of the flexor digitorum profundus tendon: A kinematic study of the human and canine digitsJournal of Orthopaedic Research, 2005
- The Double Sheath System and Tendon Gliding in Zone 2CJournal of Hand Surgery (European Volume), 1995
- Closed traumatic rupture of finger flexor pulleysThe Journal of Hand Surgery, 1994
- Functional range of motion of the joints of the handThe Journal of Hand Surgery, 1990
- Influences of flexor sheath continuity and early motion on tendon healing in dogsThe Journal of Hand Surgery, 1990
- Functional anatomy of the human digital flexor pulley systemThe Journal of Hand Surgery, 1989
- Anatomy of the finger flexor tendon sheath and pulley systemThe Journal of Hand Surgery, 1988
- Effect of pulley excision on flexor tendon biomechanicsJournal of Orthopaedic Research, 1986
- American Society for Surgery of the HandThe Journal of Hand Surgery, 1984
- Palmar aponeurosis pulleyThe Journal of Hand Surgery, 1983