Tracmor system for measuring walking energy expenditure
- 29 August 2003
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Nutrition
- Vol. 57 (9) , 1176-1180
- https://doi.org/10.1038/sj.ejcn.1601673
Abstract
Objective: Walking is an important mode of exercise and is likely to represent a major component of nonexercise activity thermogenesis. The question arises, how best to quantify walking-energy expenditure (EE) in free-living individuals. The triaxial accelerometer for movement registration (Tracmor) is a valid measure of body displacement and so we wanted to evaluate this tool for quantifying walking-EE. Hypothesis: In this study, we test the hypothesis that walking-EE, measured in a Room Calorimeter, can be predicted from Tracmor output using a regression equation derived from a brief Tracmor/treadmill/Metabolic Cart protocol. Design: First, 11 healthy subjects completed a 40-min procedure whereby they wore a Tracmor unit and walked on a treadmill at 0, 1, 2 and 3 mph while EE was measured using a Metabolic Cart. This allowed a regression equation to be defined for each subject to convert Tracmor output to EE. Each subject then entered a Room Calorimeter wearing the Tracmor Unit and walked at two self-selected velocities (‘slow’, ‘fast’) while EE was measured. ‘Tracmor/regression equation’ predictions of walking-EE were compared with Room Calorimeter measurements of walking-EE for the two velocities. Results: The ‘Tracmor/regression equation’ prediction of EE for walking slowly was 6.36±1.67 kJ/min, and for walking fast it was 11.0±2.60 kJ/min. Room Calorimeter measurements were 6.43±1.85 and 10.9±3.03 kJ/min, respectively. The intraclass correlation coefficient for slow-paced walking was 0.93 (PP<0.005). Conclusions: When combined with laboratory measures of EE, the Tracmor accelerometer provides useful data on walking-EE and is applicable to free-living individuals.Keywords
This publication has 22 references indexed in Scilit:
- Validity of four motion sensors in measuring moderate intensity physical activityMedicine & Science in Sports & Exercise, 2000
- The Energy Expended in Chewing GumNew England Journal of Medicine, 1999
- Role of Nonexercise Activity Thermogenesis in Resistance to Fat Gain in HumansScience, 1999
- Physical activity related energy expenditure in children by doubly labeled water as compared with the Caltrac accelerometerInternational Journal of Obesity, 1998
- Energy expenditure estimates of the Caltrac accelerometer for running, race walking, and steppingBritish Journal of Sports Medicine, 1997
- A triaxial accelerometer and portable data processing unit for the assessment of daily physical activityIEEE Transactions on Biomedical Engineering, 1997
- Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walkingMedical & Biological Engineering & Computing, 1997
- Energy expenditure and physical activity in subjects consuming full- or reduced-fat products aspart of their normal dietBritish Journal of Nutrition, 1996
- Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditureMedicine & Science in Sports & Exercise, 1990
- Assessment of Energy Expenditure and Fuel Utilization in ManAnnual Review of Nutrition, 1987