Automated latex nephelometric immunoassay for the measurement of serum lipoprotein (a)
- 1 January 1993
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 7 (2) , 105-110
- https://doi.org/10.1002/jcla.1860070207
Abstract
A sensitive immunoassay based on latex particle agglutination has been developed for measuring lipoprotein Lp(a) concentrations in serum or plasma. Carboxylated latex particles (diameter 240 nm) covalently coated with F(ab')2 fragments of anti-lipoprotein Lp(a) antibodies are incubated with diluted sample (400-fold) for 12 min at room temperature, with the resulting agglutination quantified by measuring the change of light-scatter produced. The assay has been automated on the Behring nephelometer analyzer with a sampling rate of 150 samples/hour. This assay generates a standard curve in the range of 27 to 1750 mg/L, showing inter-assay precision of less than 8%. There were no interferences from plasminogen, bilirubin, Intralipid™, haemoglobin, rheumatoid factor, and apolipoprotein B. No significant differences were observed when fresh and frozen samples were compared. Sample pretreatment with “Lipoclean” clearing agent and sample lyophillization decreased the agglutinating reaction. In two separate studies using 77 and 112 patient sera the Lp(a) values, determined by the latex nephelometric method, the Terumo Macra™ Lp(a) ELISA test, and the Pharmacia Apo(a) radioimmunoassay method, gave correlation coefficients of 0.948 and 0.974, respectively. Physiological lipoprotein (a) values were determined in a blood donor group, with the distribution of serum Lp(a) highly skewed, with a mean (SD) and median values of 213(236) mg/L and 116 mg/L, respectively. Concentrations of Lp(a) were found to be age-and sex-independent. This latex nephelometric procedure is a convenient method and an interesting alternative to other immunoassays for routine measurement of human lipoprotein (a).Keywords
This publication has 26 references indexed in Scilit:
- Quantitative automated latex nephelometric immunoassay for determination of myoglobin in human serumJournal of Clinical Laboratory Analysis, 1991
- Lipoprotein (a). Heterogeneity and biological relevance.Journal of Clinical Investigation, 1990
- Immunochemical characterization and quantitation of lipoprotein (a) in baboonsAtherosclerosis, 1988
- Lipoprotein Lp(a). A risk factor for myocardial infarction.Arteriosclerosis: An Official Journal of the American Heart Association, Inc., 1988
- Determination of five protein analytes using the beckman array™ and the behring nephelometer systemJournal of Clinical Laboratory Analysis, 1988
- Lipoprotein(a) as a strong indicator for cerebrovascular disease.Stroke, 1986
- A dominant role of lipoprotein(a) in the investigation and evaluation of parameters indicating the development of cervical atherosclerosisAtherosclerosis, 1985
- Diverging effects of cholestyramine on apolipoprotein B and lipoprotein Lp(a)Atherosclerosis, 1982
- Lipoprotein Lp(a) and the risk for myocardial infarctionAtherosclerosis, 1981
- Turnover of Lipoprotein (a) in ManJournal of Clinical Investigation, 1980