Application of the spirometer in respiratory gated radiotherapy
- 20 November 2003
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 30 (12) , 3165-3171
- https://doi.org/10.1118/1.1625439
Abstract
The signal from a spirometer is directly correlated with respiratory motion and is ideal for target respiratory motion tracking. However, its susceptibility to signal drift deters its application in radiotherapy. In this work, a few approaches are investigated to control spirometer signal drift for a Bernoulli-type spirometer. A method is presented for rapid daily calibration of the spirometer to obtain a flow sensitivity function. Daily calibration assures accurate airflow measurement and also reduces signal drift. Dynamic baseline adjustment further controls the signal drift. The accuracy of these techniques was studied and it was found that the spirometer is able to provide a long-term drift-free breathing signal. The tracking error is comprised of two components: calibration error and stochastic signal baseline variation error. The calibration error is very small (1% of 3 l) and therefore negligible. The stochastic baseline variation error can be as large as 20% of the normal breathing amplitude. In view of these uncertainties, the applications of spirometers in treatment techniques that rely on breathing monitoring are discussed. Spirometer-based monitoring is noted most suitable for deep inspiration breath-hold but less important for free breathing gating techniques.Keywords
This publication has 20 references indexed in Scilit:
- Breathing synchronized delivery — a new technique for radiation treatment of the targets with respiratory motionInternational Journal of Radiation Oncology*Biology*Physics, 2003
- An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRTMedical Physics, 2002
- Real‐time tumor‐tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopyCancer, 2002
- Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancerMedical Physics, 2002
- Detection of lung tumor movement in real-time tumor-tracking radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patientsMedical Physics, 2001
- Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy systemJournal of Applied Clinical Medical Physics, 2001
- Breathing‐synchronized radiotherapy program at the University of California Davis Cancer CenterMedical Physics, 2000
- Lung cancer: intermittent irradiation synchronized with respiratory motion--results of a pilot study.Radiology, 1998
- Random sample consensusCommunications of the ACM, 1981