Optimum Time of Blood Sampling for Determination of Glomerular Filtration Rate by Single-Injection [51Cr]EDTA Plasma Clearance
- 1 January 1976
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 36 (8) , 795-800
- https://doi.org/10.3109/00365517609081939
Abstract
We have investigated the influence on reproducibility of total [51Cr]EDTA plasma clearance (E) of various times and number of blood samples in patients with normal (13 patients) and low (14 patients) renal function. The study aims at fixing a clinically useful procedure suitable for all levels of renal function. Six different types of E were evaluated with time periods for blood sampling between 3 and 5 h after tracer injection, and the variation from counting radioactivity, sc, was determined as part of total variation, St. Optimum mean time, t(E), for blood sampling was calculated as a function of E, as the mean time giving the least change in E for a given change in the ‘final slope’ of the plasma curve. For patients with normal E, Sc did not contribute significantly to sr, and t(E) was about 2 h. For patients with low renal function sc contributed significantly to st, and t(E) increased steeply with decreasing E. The relative error of sc from fixed E types was calculated for all levels of renal function. The results indicate that blood sampling individualized according to predicted E values is not necessary. A sufficient precision of E can be achieved for all function levels from three blood samples drawn 180, 240, and 300 min after injection.Keywords
This publication has 7 references indexed in Scilit:
- Comparison between Total and Renal Plasma Clearance of [51Cr]EDTAScandinavian Journal of Clinical and Laboratory Investigation, 1976
- Comparison between Total and Renal Plasma Clearance of [51Cr]EDTAScandinavian Journal of Clinical and Laboratory Investigation, 1976
- Estimation of Glomerular Filtration Rate from Plasma Clearance of 51-Chromium Edetic AcidArchives of Disease in Childhood, 1972
- A Simple Method for the Determination of Glomerular Filtration RateScandinavian Journal of Clinical and Laboratory Investigation, 1972
- MEASURING GLOMERULAR FILTRATION-RATEThe Lancet, 1969
- MEASUREMENT OF GLOMERULAR FILTRATION-RATE IN MAN USING A 51Cr/EDETIC-ACID COMPLEXThe Lancet, 1967
- Appendix: DETERMINATION OF CLEARANCE AND DISTRIBUTION VOLUME WITH THE SINGLE INJECTION TECHNIQUEActa Medica Scandinavica, 1965