High field human imaging
- 20 October 2003
- journal article
- review article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (5) , 519-529
- https://doi.org/10.1002/jmri.10390
Abstract
This review article examines the state of knowledge regarding human imaging using MRI at high main magnetic field strengths. The article starts with a summary of the technical issues associated with magnetic field strengths in the range of 3–8 T, including magnet characteristics and the properties of radiofrequency magnetic fields, with special reference to sensitivity, power deposition, and homogeneity. The published data on tissue‐water relaxation times in the brain is tabulated and the implications for contrast and pulse sequence implementation is elucidated. The behavior of the major fast imaging sequences, fast low angle shot (FLASH), rapid acquisition with relaxation enhancement (RARE), and echo planar imaging (EPI), is examined in this context. A number of anatomical images from 3 T systems are presented as examples. Particular attention is given to various forms of vascular imaging, namely, time of flight angiography, venography, and arterial spin labeling. The most complex changes in contrast with main magnetic field strength are in activation studies utilizing the blood oxygen level dependent mechanism, which are examined in detail. Improvements in spatial specificity are emphasized, particularly in conjunction with spin‐echo imaging. The article concludes with a discussion of the current status and the potential impact of technical developments such as parallel imaging. J. Magn. Reson. Imaging 2003;18:519–529.Keywords
This publication has 97 references indexed in Scilit:
- Analysis and Design of Perfusion-Based Event-Related fMRI ExperimentsNeuroImage, 2002
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Detection of BOLD changes by means of a frequency‐sensitive trueFISP technique: preliminary resultsNMR in Biomedicine, 2001
- Determination of Oxygen Extraction Ratios by Magnetic Resonance ImagingJournal of Cerebral Blood Flow & Metabolism, 1999
- Localization of Cardiac-Induced Signal Change in fMRINeuroImage, 1999
- Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR dataMagnetic Resonance in Medicine, 1996
- NMR Venography Using the Susceptibility Effect Produced by DeoxyhemoglobinMagnetic Resonance in Medicine, 1992
- Reproducibility of relaxation and spin-density parameters in phantoms and the human brain measured by MR imaging at 1.5TMagnetic Resonance in Medicine, 1986
- Determinants of Proton Relaxation Rates in TissueMagnetic Resonance in Medicine, 1984
- RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imagingPhysics in Medicine & Biology, 1978