Graphical interpretation of confidence curves in rankit plots
- 5 January 2004
- journal article
- review article
- Published by Walter de Gruyter GmbH in cclm
- Vol. 42 (7) , 715-24
- https://doi.org/10.1515/cclm.2004.122
Abstract
A well-known transformation from the bell-shaped Gaussian (normal) curve to a straight line in the rankit plot is investigated, and a tool for evaluation of the distribution of reference groups is presented. It is based on the confidence intervals for percentiles of the calculated Gaussian distribution and the percentage of cumulative points exceeding these limits. The process is to rank the reference values and plot the cumulative frequency points in a rankit plot with a logarithmic (In=log(e)) transformed abscissa. If the distribution is close to In-Gaussian the cumulative frequency points will fit to the straight line describing the calculated In-Gaussian distribution. The quality of the fit is evaluated by adding confidence intervals (CI) to each point on the line and calculating the percentage of points outside the hyperbola-like CI-curves. The assumption was that the 95% confidence curves for percentiles would show 5% of points outside these limits. However, computer simulations disclosed that approximate 10% of the series would have 5% or more points outside the limits. This is a conservative validation, which is more demanding than the Kolmogorov-Smirnov test. The graphical presentation, however, makes it easy to disclose deviations from In-Gaussianity, and to make other interpretations of the distributions, e.g., comparison to non-Gaussian distributions in the same plot, where the cumulative frequency percentage can be read from the ordinate. A long list of examples of In-Gaussian distributions of subgroups of reference values from healthy individuals is presented. In addition, distributions of values from well-defined diseased individuals may show up as In-Gaussian. It is evident from the examples that the rankit transformation and simple graphical evaluation for non-Gaussianity is a useful tool for the description of sub-groups.Keywords
This publication has 30 references indexed in Scilit:
- Upper reference limit, analytical quality specifications and clinical use of haemoglobin A1CScandinavian Journal of Clinical and Laboratory Investigation, 2002
- Reproducibility of S-insulin and B-glucose responses in two identical oral glucose tolerance tests.Scandinavian Journal of Clinical and Laboratory Investigation, 2002
- Plasma glucose reference intervalin a low-risk population. 2. Impact ofthe new WHO and ADA recommendations on the diagnosis of diabetes mellitusScandinavian Journal of Clinical and Laboratory Investigation, 2001
- 7.2 Reference Intervals Based on a Danish PopulationUpsala Journal of Medical Sciences, 1994
- 7. Reference Intervals for Plasma ProteinsUpsala Journal of Medical Sciences, 1994
- Analytical Goals for the Estimation of Non-Gaussian Reference IntervalsScandinavian Journal of Clinical and Laboratory Investigation, 1989
- Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical areaScandinavian Journal of Clinical and Laboratory Investigation, 1988
- Early observations of S-myoglobin in the diagnosis of acute myocardial infarction. The influence of discrimination limit, analytical quality, patient's sex and prevalence of diseaseScandinavian Journal of Clinical and Laboratory Investigation, 1985
- 4.3. Influence of analytical quality on the diagnostic power of a single S-CK B test in patients with suspected acute myocardial infarctionScandinavian Journal of Clinical and Laboratory Investigation, 1980
- 4.2. Studies on the required analytical quality of TSH measurements in screening for congenital hypothyroidismScandinavian Journal of Clinical and Laboratory Investigation, 1980