Low‐Flux Versus High‐Flux Synthetic Dialysis Membrane in Acute Renal Failure: Prospective Randomized Study
- 1 December 2001
- journal article
- clinical trial
- Published by Wiley in Artificial Organs
- Vol. 25 (12) , 946-950
- https://doi.org/10.1046/j.1525-1594.2001.06753.x
Abstract
The influence of dialyzer membrane on the morbidity and mortality of patients with acute renal failure remains a matter of debate. The aim of the prospective randomized clinical study was to assess the influence of the flux of a synthetic dialyzer membrane on patients' survival rate, restitution of renal function, and duration of hemodialysis treatment of patients with acute renal failure as a part of multiorgan failure. Seventy‐two patients treated in intensive care units of the University Medical Center Ljubljana were randomized according to the dialyzer used throughout the duration of hemodialysis treatment. There were 38 patients in the low‐flux group (dialyzer F6, low‐flux polysuphone, Fresenius, Bad Homburg, Germany) and 34 patients in the high‐flux group (dialyzer Filtral 12, sulphonated high‐flux polyacrylonitrile, Hospal, Industrie Meyzieu, France). Both groups were balanced in terms of sex, age, APACHE II score, oliguria before dialysis, cause of acute renal failure, innotropic support, mechanical ventilation, and the number of failing organs. The patients' survival rate was 18.7% in the low‐flux group and 20.6% in the high‐flux group. Ten patients (26.3%) recovered their renal function in the low‐flux group and 8 (23.5%) in the high‐flux group. Hemodialysis treatment lasted 11.2 days in the low‐flux and 10.7 days in the high‐flux group. An analysis of subgroups with a lower mortality rate (subgroup of patients without oliguria and subgroup of patients with less than 4 failed organ systems) did not show significant differences between the low‐flux and high‐flux groups in terms of survival rate, recovery of renal function, and duration of hemodialysis treatment. In conclusion, no significant differences were found in the results of low‐flux versus high‐flux synthetic membrane dialyzer treatment in patients with acute renal failure as a part of multiorgan failure in terms of survival rate, recovery of renal function, incidence of oliguria during hemodialysis, and duration of hemodialysis treatment. The number of failing organs seems to be the most important single factor determining the survival of patients with acute renal failure as a part of multiorgan failure.Keywords
This publication has 25 references indexed in Scilit:
- Bioincompatibility of Dialyzer Membranes May Have a Negative Impact on Outcome of Acute Renal Failure, Independent of the Dose of Dialysis DeliveredAsaio Journal, 1998
- Vitamin b6 and hemodialysis: The impact of high-flux/high-efficiency dialysis and review of the literatureAmerican Journal of Kidney Diseases, 1996
- Protein catabolism in maintenance haemodialysis: the influence of the dialysis membraneNephrology Dialysis Transplantation, 1996
- Is the Choice of Membrane Important for Patients with Acute Renal Failure Requiring Hemodialysis?Artificial Organs, 1995
- Determinants of Survival and Recovery in Acute Renal Failure Patients Dialyzed in Intensive-Care UnitsAmerican Journal of Nephrology, 1991
- Outcome prediction of acute renal failure in medical intensive careIntensive Care Medicine, 1991
- Activation of complement by hemodialysis membranes: Polyacrylonitrile binds more C3a than cuprophanKidney International, 1990
- Easy and Early Prognosis in Acute Tubular Necrosis: A Forward Analysis of 228 CasesNephron, 1989
- APACHE IICritical Care Medicine, 1985
- Acute renal failure in an intensive care unit: incidence, prediction and outcomeAnaesthesia, 1983