Different benefit of bispectal index (BIS™) in desflurane and propofol anesthesia
- 1 February 2003
- journal article
- clinical trial
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 47 (2) , 165-173
- https://doi.org/10.1034/j.1399-6576.2003.00041.x
Abstract
Bispectal index (BIS) monitoring may reduce drug usage and hasten recovery in propofol and inhalation anesthesia. The faster emergence profile of desflurane may reduce the effect of BIS monitoring on recovery from desflurane compared with propofol. This study compared hypnotic drug usage, recovery, patient satisfaction and incidence of inadequate sedation in BIS monitored and nonmonitored women anesthetized with desflurane or propofol. One hundred and sixty patients scheduled for elective gynecological surgery were randomly assigned to desflurane or propofol anesthesia with and without BIS monitoring. Fentanyl, vecuronium and remifentanil were administered according to clinical criteria. The BIS monitor was used in all patients, but the monitor screen was covered in the controls. A BIS level between 45 and 55 was targeted in the BIS monitored patients whereas depth of anesthesia was assessed by clinical criteria in the controls. The mean (SD) desflurane MAC-hours administered with and without BIS were 0.70 (0.15) and 0.76 (0.12), respectively, resulting in extubation times of 6.5 (4.1) and 8.3 (6.1) min. (NS). Bispectal index monitoring was associated with improved patient satisfaction, reduced postoperative nausea and antiemetic drug requirement, and fewer episodes with sustained BIS levels > 60. The mean (SD) propofol infusion rates were 6.0 (1.4) and 6.6 (0.9) mg kg(-1)h(-1) with and without the BIS monitor (P = 0.023), resulting in mean (SD) extubation times of 6.8 (4.6) and 10.5 min (5.9), respectively (P < 0.05). Bispectal index monitoring reduced propofol usage and hastened recovery after propofol anesthesia, whereas in desflurane anesthesia it was associated with improved patient satisfaction, probably because of decreased postoperative nausea and fewer episodes of inadequate hypnosis.Keywords
This publication has 26 references indexed in Scilit:
- Sevoflurane Titration Using Bispectral Index Decreases Postoperative Vomiting in Phase II Recovery After Ambulatory SurgeryAnesthesia & Analgesia, 2001
- The post-anesthesia recovery score revisitedPublished by Elsevier ,2000
- Computer Simulation to Determine How Rapid Anesthetic Recovery Protocols to Decrease the Time for Emergence or Increase the Phase I Postanesthesia Care Unit Bypass Rate Affect Staffing of an Ambulatory Surgery CenterAnesthesia & Analgesia, 1999
- EEG bispectral index monitoring in sevoflurane or propofol anaesthesia: analysis of direct costs and immediate recoveryActa Anaesthesiologica Scandinavica, 1999
- Computer Simulation to Determine How Rapid Anesthetic Recovery Protocols to Decrease the Time for Emergence or Increase the Phase I Postanesthesia Care Unit Bypass Rate Affect Staffing of an Ambulatory Surgery CenterAnesthesia & Analgesia, 1999
- Is the Bispectral Index Useful in Predicting Fast-Track Eligibility After Ambulatory Anesthesia with Propofol and Desflurane?Anesthesia & Analgesia, 1998
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997
- Awakening, Clinical Recovery, and Psychomotor Effects After Desflurane and Propofol AnesthesiaAnesthesia & Analgesia, 1996
- Awakening, Clinical Recovery, and Psychomotor Effects After Desflurane and Propofol AnesthesiaAnesthesia & Analgesia, 1996