Effect of posterior chamber intraocular lens design and surgical placement on postoperative outcome
- 1 July 1992
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 18 (4) , 333-341
- https://doi.org/10.1016/s0886-3350(13)80067-3
Abstract
Intraocular lens (IOL) design, optical configuration, and placement have potential effects on postoperative outcome. Laboratory studies have suggested that one-piece, biconvex designs may reduce or delay posterior capsular opacification and that in-the-bag fixation of the posterior chamber IOL may reduce inflammation. To document the clinical significance of IOL design and placement, we conducted a randomized, prospective, clinical trial. Six hundred uncomplicated capsulorhexis and phacoemulsification patients were randomized in a three-factor design to receive an IOL that was one-piece or three-piece, had a biconvex, plano-convex, or laser ridge optic, and was bag-or sulcus-fixated. Treatment differences were related to lens placement. Patients with bag-fixated IOLs had less posterior capsular opacification, fewer YAG laser capsulotomies, a higher percentage of centered lenses, less inflammation, and fewer late posterior capsular striae than those with sulcus-fixated IOLs. In the latter group, patients with three-piece IOLs had fewer posterior capsular striae at three months postoperatively. All six occurrences of haptic loop distortion were in patients with three-piece IOLs. Patients with the one-piece design had less late inflammation than those with the three-piece design. Fewer YAG capsulotomies were necessary at one year in patients with the biconvex design than in those with the plano-convex or laser ridge configurations. Operative complications, endothelial cell loss, and postoperative complications were not IOL-related.Keywords
This publication has 17 references indexed in Scilit:
- Side-View Analysis of the LensArchives of Ophthalmology (1950), 1992
- Side-View Analysis of the LensArchives of Ophthalmology (1950), 1992
- A method to study the interaction between intraocular lens loops and anterior segment vasculatureJournal of Cataract & Refractive Surgery, 1989
- Posterior capsular opacification and intraocular lens decentration Part II: Experimental findings on a prototype circular intraocular lens designJournal of Cataract & Refractive Surgery, 1988
- Posterior capsular opacification and intraocular lens decentration Part I: Comparison of various posterior chamber lens designs implanted in the rabbit modelJournal of Cataract & Refractive Surgery, 1988
- Decentration of Flexible Loop Posterior Chamber Intraocular Lenses in a Series of 222 Postmortem EyesOphthalmology, 1988
- Posterior chamber intraocular lenses in a series of 75 autopsy eyes Part I: Loop locationJournal of Cataract & Refractive Surgery, 1986
- Evaluating the intraocular lens opticSurvey of Ophthalmology, 1986
- A comparison of ciliary sulcus and capsular bag fixation of posterior chamber intraocular lensesAmerican Intra-Ocular Implant Society Journal, 1985
- Complications of intraocular lenses. A historical and histopathological reviewSurvey of Ophthalmology, 1984