Incorporation of Horseradish Peroxidase in a Kieselguhr Membrane and the Application to a Mediator-free Hydrogen Peroxide Sensor
- 19 February 2001
- journal article
- Published by Springer Nature in Analytical Sciences
- Vol. 17 (2) , 273-276
- https://doi.org/10.2116/analsci.17.273
Abstract
Horseradish peroxidase was incorporated in a kieselguhr membrane. The electron-transfer process of the enzyme was examined by cyclic voltammetry. It was observed that the electron-transfer reactivity of horseradish peroxidase was greatly enhanced, and that direct electrochemistry was accordingly feasible. Using the merits of the direct electron-transfer reactivity of horseradish peroxidase and its specific enzymatic catalysis towards hydrogen peroxide, an unmediated hydrogen peroxide biosensor was constructed. The calibration plot of this hydrogen peroxide sensor was linear in the range of 2.0 x 10(-6) mol/L - 6.5 x 10(-4) mol/L. The relative standard deviation was 4.1% for 6 successive determinations at a concentration of 1.0 x 10(-4) mol/L. The detection limit was 1.0 x 10(-6) mol/L.Keywords
This publication has 37 references indexed in Scilit:
- Fabrication of multilayer films containing horseradish peroxidase and polycation-bearing Os complex by means of electrostatic layer-by-layer adsorption and its application as a hydrogen peroxide sensorAnalytica Chimica Acta, 2000
- Characterization of the direct electron transfer and bioelectrocatalysis of horseradish peroxidase in DNA film at pyrolytic graphite electrodeAnalytica Chimica Acta, 2000
- Sol–gel materials for electrochemical biosensorsAnalytica Chimica Acta, 1999
- A reagentless hydrogen peroxide sensor based on incorporation of horseradish peroxidase in poly(thionine) film on a monolayer modified electrodeAnalytica Chimica Acta, 1999
- Hydrogen peroxide sensor based on horseradish peroxidase-labeled Au colloids immobilized on gold electrode surface by cysteamine monolayerAnalytica Chimica Acta, 1999
- A reagentless amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene green in a modified zeolite matrixAnalytica Chimica Acta, 1999
- Direct electrochemistry of membrane-entrapped horseradish peroxidase.Bioelectrochemistry and Bioenergetics, 1998
- Minizymes. A new strategy for the development of reagentless amperometric biosensors based on direct electron-transfer processesBioelectrochemistry and Bioenergetics, 1997
- Bulk modified enzyme electrodes for reagentless detection of peroxidesBioelectrochemistry and Bioenergetics, 1991
- Drinking-water treatment with ozoneEnvironmental Science & Technology, 1987