Isolation of Legionella from water samples using various culture methods
- 1 February 1994
- journal article
- research article
- Published by Wiley in Journal of Applied Bacteriology
- Vol. 76 (2) , 155-162
- https://doi.org/10.1111/j.1365-2672.1994.tb01611.x
Abstract
The efficacy of a non-selective medium and two selective media were compared for the isolation of legionellas from water samples. The effect of acid wash treatment for decontamination of the water samples on the isolation frequency of legionellas was also studied. The 236 samples were taken from cooling, humidifying and drinking water systems; 21% were legionella-positive when inoculated directly on modified Wadowsky-Yee (MWY) medium and 26% were positive when concentrated (x 200) before cultivation on MWY or CCVC media. Inoculation on MWY medium after concentration followed by decontamination by the acid-wash technique gave the highest isolation frequency (31%). The lowest frequency (8%) was found with the non-selective BCYE alpha medium. An isolation frequency of 28% was achieved with the BCYE alpha medium after concentration and acid-wash treatment of the samples. Forty per cent of the samples were positive for legionellas when the results from all the culture methods were combined. Not all the legionella-positive samples were identified by a single culture method. Ninety-three of the 95 positive samples were detected with the two best combinations of three culture methods. The best culture method for detecting legionellas depended on the source of the water sample. Some water quality characteristics, like temperature and organic matter content, affected the isolation frequency of Legionella spp.Keywords
This publication has 25 references indexed in Scilit:
- Comparative study of procedures for isolation and cultivation of Legionella pneumophila from tap water in hospitalsJournal of Clinical Microbiology, 1993
- Physical, chemical and microbiological water characteristics associated with the occurrence of Legionella in cooling tower systemsWater Research, 1993
- Inhibition of growth ofLegionella species by heterotrophic plate count bacteria isolated from chlorinated drinking waterCurrent Microbiology, 1990
- Legionella pneumophila: comparison of isolation from water specimens by centrifugation and filtrationEpidemiology and Infection, 1987
- A note on the temperature tolerance of LegionellaJournal of Applied Bacteriology, 1984
- Isolation of Legionella pneumophila from Cooling Tower Water by FiltrationApplied and Environmental Microbiology, 1981
- Legionella pneumophila: Growth Inhibition by Human Pharyngeal FloraThe Journal of Infectious Diseases, 1980
- Legionnaires' DiseaseNew England Journal of Medicine, 1977
- A RAPID AND PRECISE METHOD FOR THE DETERMINATION OF UREAJournal of Clinical Pathology, 1960