High‐resolution capillary array electrophoretic sizing of multiplexed short tandem repeat loci using energy‐transfer fluorescent primers
- 1 January 1996
- journal article
- application
- Published by Wiley in Electrophoresis
- Vol. 17 (9) , 1485-1490
- https://doi.org/10.1002/elps.1150170913
Abstract
Short tandem repeat regions (STRs) from the polymorphic loci VWFA, THO1, TPO and CSF were amplified by the multiplex polymerase chain reaction (PCR) and analyzed by capillary array electrophoresis with fluorescence detection of energy transfer (ET) labels. The fluorescent ET primers are labeled with one fluorescein at the 5′ end and a second fluorescein at the position of the 7th or 9th (modified) base to produce fragments that fluoresce in the green (λmax = 525 nm). M13 A‐track sequencing fragments, used as an internal sizing standard, were generated with a universal primer that has a donor fluorescein at the 5′ end and a rhodamine acceptor at the position of the 11th (modified) base to produce fragments fluorescing in the red (> 590 nm). The labeled DNA fragments were excited at 488 nm, and the fluorescence was detected with a two‐color confocal fluorescence scanner. Separations were performed on arrays of hollow fused silica capillaries filled with denaturing and replaceable hydroxyethyl cellulose sieving matrices. Separations were complete in less than 50 min, and single base resolution as well as reproducible STR sizing was achieved. The relative standard deviation in sizing was below 0.6%. This work establishes the feasibility of high‐resolution, high‐speed and high‐throughput STR typing of single‐stranded DNA fragments using capillary array electrophoresis.Keywords
This publication has 23 references indexed in Scilit:
- Molecular Detection of Primary Bladder Cancer by Microsatellite AnalysisScience, 1996
- Rapid Sizing of Short Tandem Repeat Alleles Using Capillary Array Electrophoresis and Energy-Transfer Fluorescent PrimersAnalytical Chemistry, 1995
- The evolutionary dynamics of repetitive DNA in eukaryotesNature, 1994
- High-Sensitivity Capillary Electrophoresis of Double-Stranded DNA Fragments Using Monomeric and Dimeric Fluorescent Intercalating DyesAnalytical Chemistry, 1994
- The 1993–94 Généthon human genetic linkage mapNature Genetics, 1994
- Laser-excited confocal-fluorescence gel scannerReview of Scientific Instruments, 1994
- Automated DNA profiling employing multiplex amplification of short tandem repeat loci.Genome Research, 1993
- Capillary array electrophoresis: an approach to high-speed, high-throughput DNA sequencingNature, 1992
- Capillary array electrophoresis using laser-excited confocal fluorescence detectionAnalytical Chemistry, 1992
- Survey of human and rat microsatellitesGenomics, 1992