Effect of ablation profile on wound healing and visual performance 1 year after excimer laser photorefractive keratectomy.
Open Access
- 1 March 1996
- journal article
- clinical trial
- Published by BMJ in British Journal of Ophthalmology
- Vol. 80 (3) , 224-234
- https://doi.org/10.1136/bjo.80.3.224
Abstract
BACKGROUND: Early photorefractive keratectomy ablations were of limited diameter and depth to maintain the integrity of the globe and to minimise postoperative haze. This study evaluated the effects of deeper, larger diameter wounds on refractive stability and corneal haze, and investigated the effects of ablation profile on wound healing and visual performance. METHODS: One hundred patients undergoing -3.00D and -6.00D corrections were randomised to receive 5 mm, 6 mm, or multizone treatments. The multizone treatment was 6 mm in diameter, but only the depth of the 5 mm treatment. Outcome was measured by Snellen visual acuity, residual refractive error, objective techniques for haze and halos, pupil diameter, subjective night vision, and requirement for retreatment. RESULTS: Overall, the results of 6 mm treatments were superior to those of 5 mm and multizone treatments: they had a smaller hyperopic shift (p < 0.01), a more predictable (p < 0.001) and stable refractive outcome, less haze (p < 0.05), smaller halos (p < 0.05), fewer subjective night vision problems, and fewer patients required retreatment. CONCLUSIONS: Analysis of these data and a literature review of corneal wound healing demonstrated that the improved outcome associated with the 6 mm beam did not relate to the depth of ablation. The factor with greatest apparent influence on the development of haze and regression was the slope of the wound surface over the entire area of the ablation. Tapering the wound edge provided no additional benefit, and contributed to night vision problems. It is, therefore, recommended that small diameter or multizone treatments should not be used in low and moderate myopia.Keywords
This publication has 74 references indexed in Scilit:
- Disturbances in night vision after excimer laser photorefractive keratectomyEye, 1994
- Treatment of band keratopathy by excimer laser phototherapeutic keratectomy: surgical techniques and long term follow up.British Journal of Ophthalmology, 1993
- Clinical Use of the 193-nm Excimer Laser in the Treatment of Corneal ScarsArchives of Ophthalmology (1950), 1991
- A Comparison of En Face and Tangential Wide-Area Excimer Surface Ablation in the RabbitArchives of Ophthalmology (1950), 1990
- Corneal Stromal Wound Healing in Rabbits After 193-nm Excimer Laser Surface AblationArchives of Ophthalmology (1950), 1989
- Assessment of corneal wound repairin vitroCurrent Eye Research, 1989
- Corneal Endothelial Injury in Rabbits Following Excimer Laser Ablation at 193 and 248 nmArchives of Ophthalmology (1950), 1986
- A comparative study of corneal incisions induced by diamond and steel knives and two ultraviolet radiations from an excimer laser.British Journal of Ophthalmology, 1986
- Quantitation of Corneal Ablation by Ultraviolet Laser LightArchives of Ophthalmology (1950), 1985
- The Tensile Strength of Corneal WoundsArchives of Ophthalmology (1950), 1968