Effect of post‐excitation radius on ion abundance, mass measurement accuracy, and isotopic distributions in Fourier transform ion cyclotron resonance mass spectrometry
- 4 March 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (7) , 915-918
- https://doi.org/10.1002/rcm.1871
Abstract
We report an evaluation of a modern Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR‐MS) instrument to determine the general trend of post‐excitation radius on total ion abundance, mass measurement accuracy, and isotopic distributions for internally calibrated mass spectra. The optimum post‐excitation radius was determined using total ion abundance, mass measurement accuracy (MMA), and isotope ratios. However, despite the utility of internal calibration for achieving ultimate MMA, the internal calibrant ions were insufficient for compensating for sub‐optimum ICR cell conditions. The findings presented herein underscore the importance of determining the optimal post‐excitation radius in FT‐ICR‐MS to achieve high ion abundance (low limits of detection), high MMA, and valid isotopic distributions. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 29 references indexed in Scilit:
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Ion traps for Fourier transform ion cyclotron resonance mass spectrometry: principles and design of geometric and electric configurationsInternational Journal of Mass Spectrometry and Ion Processes, 1995
- Image charge-induced ion cyclotron orbital frequency shift for orthorhombic and cylindrical FT-ICR ion trapsInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Open trapped ion cell geometries for Fourier transform ion cyclotron resonance mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1992
- Modelling coulomb effects in Fourier‐transform ion cyclotron resonance mass spectrometry by charged disks and charged cylindersRapid Communications in Mass Spectrometry, 1992
- Simple physical models for coulomb‐induced frequency shifts and coulomb‐induced inhomogenous broadening for like and unlike ions in fourier transform ion cyclotron resonance mass spectrometryRapid Communications in Mass Spectrometry, 1991
- Experimental determination of the effects of space charge on ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983
- Theory of space-charge shift of ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983
- Exact mass measurement in the absence of calibrant by Fourier transform mass spectrometryAnalytical Chemistry, 1983
- Signal modeling for ion cyclotron resonanceThe Journal of Chemical Physics, 1978