Routine analysis by high precision gas chromatography/mass selective detector/isotope ratio mass spectrometry to 0.1 parts per mil
- 28 June 1999
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 13 (13) , 1231-1236
- https://doi.org/10.1002/(sici)1097-0231(19990715)13:13<1231::aid-rcm579>3.0.co;2-b
Abstract
Stable isotope methods are potentially quite useful for validating natural or enhanced mineral degradation of contaminants. For this reason, a continuous flow gas chromatograph (GC), isotope ratio mass spectrometer (IRMS) has been coupled with a quadrupole mass selective detector (MSD) to allow simultaneous mass spectral and stable carbon isotope ratio data to be obtained from a single chromatographic analysis. This allows the target contaminant and any extra‐cellular degradation intermediates to be both qualified and quantified. Previously acceptable limits of precision (0.3 parts per mil) are undesirable given the small fractionation observed during aerobic degradation. To further understand the fate of organic contaminants and to gain information about the metabolic degradative pathway employed by a microorganism, routine isotopic analyses on a range of analytes have been performed. Quantities of sample producing mass‐44 ion beam signal (I44) of 2 × 10−10 to 1 × 10−8 A were analysed. When the IRMS was tuned for high sensitivity, ion source nonlinearities were overcome by peak height correction from an algorithm that was produced using known isotopic standards of varying concentrations. This led to sample accuracy of <0.01‰ and sample precision of 0.1‰. Copyright © 1999 John Wiley & Sons, Ltd.Keywords
This publication has 14 references indexed in Scilit:
- Tracing Organic Contaminants in Groundwater: A New Methodology Using Compound-Specific Isotopic AnalysisEnvironmental Science & Technology, 1997
- Use of Stable Oxygen and Carbon Isotope Analyses for Monitoring the Pathways and Rates of Intrinsic and Enhanced in Situ BiodegradationEnvironmental Science & Technology, 1997
- Stable Carbon Isotope Evidence of Biodegradation Zonation in a Shallow Jet-Fuel Contaminated AquiferEnvironmental Science & Technology, 1996
- Characterisation of Refractory Wastes at Heavy Oil-Contaminated Sites: A Review of Conventional and Novel Analytical MethodsEnvironmental Technology, 1995
- On‐line recording of 13C/12C ratios and mass spectra in one gas chromatographic analysisJournal of High Resolution Chromatography, 1995
- Isotope-ratio-monitoring gas chromatography-mass spectrometry: methods for isotopic calibrationOrganic Geochemistry, 1994
- Bridging the information gap between isotope ratio mass spectrometry and conventional mass spectrometryJournal of Mass Spectrometry, 1994
- Automated measurement of13C enrichment in carbon dioxide derived from submicromole quantities of L-(1-13C)-leucineJournal of Mass Spectrometry, 1988
- Isotope-ratio-monitoring gas chromatography-mass spectrometryAnalytical Chemistry, 1978
- A new technique for the detection of metabolites labelled by the isotope13C using mass fragmentographyJournal of Mass Spectrometry, 1976