Abstract
This paper describes a novel application of ultrasonic Lamb waves combined with network methods for data analysis for a non-destructive evaluation of the adhesive fillet size in the cusp of an aluminium T-peel joint. The ultrasonic signals were transmitted and received using a purpose-built cross correlator system, which generated filtered pseudo-random binary sequences tailored to excite s0 and a1 wave modes in the specimens. Signals received after propagation across the joint area were analysed in the modulus frequency domain by means of a standard fast Fourier transform. Simple statistical measures (such as mean and standard deviation) applied to peaks in the frequency spectra did not provide a robust basis for automatic discrimination between classes of bond fillet size, with 'recognition' success being of the order of chance alone. The most basic form of artificial neural network, the linear network, was then trained to recognize bond fillet radius as belonging to one of three categories of size. When presented with regions of bond fillet that were not included in its training data, it was able to 'recognize' fillet sizes with a success rate of 95%. The sensitivity of the method to experimental arrangements was examined by comparing the results obtained with well-collimated water-coupled transducers with those obtained by using mode-converting contact probes, which exhibited greater angular dispersion in the excited waves. Comparisons were made between different transducer excitations designed to excite s0 alone, a1 alone, s0 and a1 together and also a broadband excitation. Various training protocols for the network were also compared as were the results of output thresholding to minimize the number of wrong decisions made by the network. Overall we find that the best fillet size recognition performance was obtained with the broadband excitation applied to mode-converting wedge transducers set on either side of the bond.Keywords
This publication has 7 references indexed in Scilit:
- Lamb wave interaction with lap-shear adhesive joints: Theory and experimentThe Journal of the Acoustical Society of America, 1991
- A two-dimensional Fourier transform method for the measurement of propagating multimode signalsThe Journal of the Acoustical Society of America, 1991
- Near-plane-wave acoustic propagation measurements in thin layers of adhesive polymerMeasurement Science and Technology, 1991
- Leaky Lamb Waves for the Ultrasonic Nondestructive Evaluation of Adhesive BondsJournal of Engineering Materials and Technology, 1990
- Recent Advances in the Application of Leaky Lamb Waves to the Nondestructive Evaluation of Adhesive BondsThe Journal of Adhesion, 1989
- Coupling of Lamb waves with the aperture between two elastic sheetsThe Journal of the Acoustical Society of America, 1983
- Complementary seriesIEEE Transactions on Information Theory, 1961