High mass accuracy in‐source collision‐induced dissociation tandem mass spectrometry and multi‐step mass spectrometry as complementary tools for fragmentation studies of quaternary ammonium herbicides
- 3 August 2004
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 39 (8) , 873-883
- https://doi.org/10.1002/jms.648
Abstract
Fragmentation studies using both an ion-trap mass analyzer and a hybrid quadrupole time-of-flight (Q-TOF) mass spectrometer were performed in order to establish the fragmentation pathways of organic molecules. A general strategy combining MSn data (n = 1–4) in an ion-trap analyzer with tandem mass spectrometry and in-source collision-induced dissociation tandem mass spectrometry (CID MS/MS) in a Q-TOF instrument was applied. The MSn data were used to propose a tentative fragmentation pathway following genealogical relationships. When several assignments were possible, MS/MS and in-source CID MS/MS (Q-TOF) allowed the elemental compositions of the fragments to be confirmed. Quaternary ammonium herbicides (quats) were used as test compounds and their fragmentation pathways were established. The elemental composition of the fragments was confirmed using the TOF analyzer with relative errors <0.0023 Da. Some fragments previously reported in the literature were reassigned taking advantage of the high mass resolution and accuracy of the Q-TOF instrument, which made it possible to solve losses where nitrogen was involved. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 24 references indexed in Scilit:
- Analysis of high mass peptides using a novel matrix‐assisted laser desorption/ionisation quadrupole ion trap time‐of‐flight mass spectrometerRapid Communications in Mass Spectrometry, 2003
- Multistep mass spectrometry of heterocyclic amines in a quadrupole ion trap mass analyserJournal of Mass Spectrometry, 2002
- Formation of gas-phase clusters monitored during electrospray mass spectrometry: a study of quaternary ammonium pesticidesRapid Communications in Mass Spectrometry, 2001
- Tandem mass spectrometric analysis of quaternary ammonium pesticidesRapid Communications in Mass Spectrometry, 2001
- Optimisation of the quantitative determination of chlormequat by matrix‐assisted laser desorption/ionisation mass spectrometryRapid Communications in Mass Spectrometry, 2001
- Determination of Diquat and Paraquat in Water by Liquid Chromatography/Electrospray–Mass Spectrometry Using Volatile Ion-Pairing ReagentsAnalytical Sciences, 2000
- Electrospray multistep ion trap mass spectrometry for the structural characterisation of poly[(R,S)-3-hydroxybutanoic acid] containing a ?-lactam end groupRapid Communications in Mass Spectrometry, 2000
- Capillary electrophoresis time-of-flight mass spectrometry of paraquat and diquat herbicidesJournal of Microcolumn Separations, 1999
- Continuous-Flow MALDI Mass Spectrometry Using an Ion Trap/Reflectron Time-of-Flight DetectorAnalytical Chemistry, 1995
- Mass spectrometry of some imidazoles of pharmacological interestRapid Communications in Mass Spectrometry, 1994