The effect of detector performance on high count rate PET imaging with a tomograph based on position-sensitive detectors
- 1 February 1988
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 35 (1) , 592-597
- https://doi.org/10.1109/23.12793
Abstract
Emission-computed tomography systems using large position-sensitive detectors must handle high event rates per detector during dynamic studies. To determine the ability of their positron-emission tomograph (PET) to perform high-count-rate scans, the authors have studied detector performance up to single rates in excess of 2 million counts per second per detector. To evaluate the quality of images resulting from data acquired at these rates, signal-to-noise ratio analyses were applied to both simulated and experimental high-count-rate images of a cold-spot phantom. Changes in image quality were quantitated, allowing the testing of combinations of high-count-rate event processing techniques to produce optimal high-count-rate images. It was found that severe image degradation occurs when the centroid positioning algorithm is used, due to the long tails in the detector point speed function that result at high count rates. Image quality is greatly improved when the local centroid event-positioning algorithm is used to eliminate the tails. Further improvements are possible with shorter integration time and an upper-level energy discriminator set at 600 keV, close to the photopeak.Keywords
This publication has 13 references indexed in Scilit:
- Indices of discrimination or diagnostic accuracy: Their ROCs and implied models.Psychological Bulletin, 1986
- Triangular Spect System for 3-D Total Organ Volume Imaging: Design Concept and Preliminary Imaging ResultsIEEE Transactions on Nuclear Science, 1985
- One- and Two-Dimensional Position Sensitive Scintillation Detectors for Thermal NeutronsIEEE Transactions on Nuclear Science, 1985
- Resolution and Linearity of Anger-Type Neutron-Position Detectors as Simulated with Different Signal Processing and OpticsIEEE Transactions on Nuclear Science, 1985
- A Fast Parallel Encoding Scheme for the Anger CameraIEEE Transactions on Nuclear Science, 1984
- Human Signal Detection Performance For Noisy Medical ImagesPublished by SPIE-Intl Soc Optical Eng ,1982
- Properties Of Statistical Noise In Positron Emission TomographyPublished by SPIE-Intl Soc Optical Eng ,1982
- LESION DETECTION WITH SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY (SPECT) COMPARED WITH CONVENTIONAL IMAGINGJournal of Computer Assisted Tomography, 1982
- Image Noise, Resolution, and Lesion Detectability in Single Photon Emission CTIEEE Transactions on Nuclear Science, 1982
- A comparison of optimum detector spatial resolution in nuclear imaging based on statistical theory and on observer performancePhysics in Medicine & Biology, 1978