Gray Level Transforms and Lesion Detectability in Echographic Images
- 1 July 1988
- journal article
- research article
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 10 (3) , 171-195
- https://doi.org/10.1177/016173468801000302
Abstract
In search of the optimal display of echographic information for the detection of focal lesions, a systematic study was performed considering a wide range of gray level transforms (i.e., lookup tables). This range comprised power functions of the echo envelope signal (1/8 ≤ n ≤ 8), power functions of the logarithmic transform and a sigmoid function. The implications of the transforms on the first order statistics (histogram, “point signal-to-noise ratio” SNRp) and on the second order statistics (autocorrelation function) could be derived both analytically, and from the analysis of simulated and experimentally obtained echograms of homogeneously scattering tissue models. These results were employed to estimate the lesion signal-to-noise ratio SNRQ, which specifies the detectability of a lesion by an ideal observer. It was found, both theoretically and practically, that the intensity display corresponds to the optimal transform (i.e., n=2) for a low contrast lesion. When the data were first logarithmically compressed, the lesion SNR appeared to increase with increasing power (1/8 ≤ n ≤ 8). A logarithmic transform followed by a sigmoid compression did not produce much improvement. These effects of gray level transforms on the SNRQ were shown to be relatively small, with the exception of powers n > 2 when applied to linear (i.e. amplitude) data. In the case of high lesion contrast, the sequence of log compression, followed by a square law produced the optimum SNRQ. This sequence is equivalent to the processing within echographic equipment, where the TV monitor has a gamma of the order of 2.Keywords
This publication has 18 references indexed in Scilit:
- Unified SNR analysis of medical imaging systemsPhysics in Medicine & Biology, 1985
- Texture of B-Mode Echograms: 3-D Simulations and Experiments of the Effects of Diffraction and Scatterer DensityUltrasonic Imaging, 1985
- Texture in B-Mode Echograms: A Simulation Study of the Effects of Diffraction and of Scatterer Density on Gray Scale StatisticsPublished by Springer Nature ,1985
- Computer Simulations of Speckle in B-Scan ImagesUltrasonic Imaging, 1983
- The Improvement and Quantitative Assessment of B-Mode Images Produced by an Annular Array/Cone HybridUltrasonic Imaging, 1983
- Low Contrast Detectability and Contrast/Detail Analysis in Medical UltrasoundIEEE Transactions on Sonics and Ultrasonics, 1983
- Statistics of Speckle in Ultrasound B-ScansIEEE Transactions on Sonics and Ultrasonics, 1983
- Ultrasonic B-scanning: a computer simulationPhysics in Medicine & Biology, 1980
- Acoustic Speckle: Theory and Experimental AnalysisUltrasonic Imaging, 1979
- Speckle in ultrasound B-mode scansIEEE Transactions on Sonics and Ultrasonics, 1978