Coronary angiography: an analysis of radiographic practice in the UK
- 1 April 1993
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 66 (784) , 327-331
- https://doi.org/10.1259/0007-1285-66-784-327
Abstract
There is growing public and professional concern over the risks of medical ionizing radiation. It is therefore important to examine our procedures for ways in which we can reduce radiation dose to patients and staff. We surveyed 48 catheter laboratories nationwide to establish the range of practice in performing “routine” coronary angiography and left ventriculography. There were wide variations in the numbers of views obtained, mean ciné film lengths and mean fluoroscopy times. Despite the recommendation of the National Radiological Protection Board, only five of the 36 centres responding were able to provide estimates of patient radiation dose per procedure. Calculations of maximum and minimum patient doses, based on ciné film length and fluoroscopy time, show a fourfold variation between hospitals. Using the concept of estimated dose equivalent, the predicted lifetime fatal cancer risk for a routine examination ranges from 1/16 600 to 1/4300. As a preliminary step in radiation dose reduction we have used this survey data to suggest how a typical coronary angiogram and left ventriculogram might be performed.Keywords
This publication has 11 references indexed in Scilit:
- How will the new definition of 'effective dose' modify estimates of dose in diagnostic radiology?Journal of Radiological Protection, 1991
- Patient dose reduction in diagnostic radiologyClinical Radiology, 1991
- Relations between effective dose equivalent and mean absorbed dose (energy imparted) to patients in diagnostic radiologyPhysics in Medicine & Biology, 1986
- An investigation of the radiation dose to staff during cardiac radiological studiesThe British Journal of Radiology, 1985
- Energy imparted to the patient in diagnostic radiology: calculation of conversion factors for determining the energy imparted from measurements of the air collision kerma integrated over beam areaPhysics in Medicine & Biology, 1984
- Terminology for radiographic projections in cardiac angiographyCatheterization and Cardiovascular Diagnosis, 1981
- Patient exposure in cardiac catheterization and cinefluorography using the Eclair 16 mm camera at speeds up to 200 frames per secondThe British Journal of Radiology, 1974
- Radiation dose to the patient in cardiac radiologyThe British Journal of Radiology, 1970