Field Tests on a 345-Kv High-Capacity Oil Circuit Breaker at Philip Sporn Power Plant
- 1 April 1959
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems
- Vol. 78 (3) , 829-841
- https://doi.org/10.1109/AIEEPAS.1959.4500446
Abstract
1. A 345-kv OCB rated 25,000, was tested extensively at the Philip Sporn Station of the AEP system for performance on both line-dropping and fault-interruption duty. 2. The full-scale tests demonstrated the adequacy of the breaker over an extremely wide range of fault conditions and for line-charging current-switching duty up to and beyond the present maximum lineswitching requirements of the AEP system at 345 kv. 3. The line-dropping tests were free of the high transient overvoltages which accompany severe restrikes. In 57 3 phase tests at currents up to 226 amperes, there were three single restrikes with maximum transient voltages lower than those accompanying normal fault interruptions. 4. Fault duty tests included singlephase as well as both grounded and ungrounded 3-phase faults, high-speed reclosing, and a 4-operation AEP reclosing duty cycle at fault duties between 1,160 and 13,380 mva. The tests confirmed the usefulness of field tests and inspired confidence in the results of laboratory tests previously reported.2 5. The field tests also demonstrated the more severe duty imposed on a circuit breaker by 3-phase ungrounded faults. Arcing times for 3-phase ungrounded faults were found to be approximately one half-cycle longer than for grounded faults because of the higher power-frequency recovery voltage across the first pole to clear. Because of the rarity of 3-phase ungrounded faults in service, it is the opinion of the authors that industry standards should recognize a longer applicable rated interrupting time for this type of fault for breakers intended for application on effectively grounded systems.Keywords
This publication has 5 references indexed in Scilit:
- Advanced Interrupter Design for 230- and 345-Kv Oil Circuit BreakersTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1958
- Transient Recovery Voltages on Power Systems Part II - Practical Methods of DeterminationTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1958
- Severe Rates of Rise of Recovery Voltage Associated with Transmission Line Short CircuitsTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1957
- System Recovery Voltage and Short-Circuit Duty for High-Voltage Circuit Breakers [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1953
- Operating Mechanisms for High-Capacity High-Voltage Oil Circuit Breakers [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1953