Characterization of PCR Products from Bacilli Using Electrospray Ionization FTICR Mass Spectrometry
- 1 November 1996
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (21) , 3705-3712
- https://doi.org/10.1021/ac960689j
Abstract
A procedure for rapid purification of polymerase chain reaction (PCR) products allowing precise molecular weight determination using electrospray ionization-Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry is described. PCR amplification utilized the DNA polymerase from Pyrococcus furiosus (Pfu) which, unlike Taq, does not incorporate a nontemplated terminal deoxyadenosine phosphate. An 89-base pair nucleotide portion of the spacer region between the 16S and 23S ribosomal rRNA genes was amplified from the genome of three members of Bacillus cereus group and a 114 nucleotide region from the Bacillus subtilis. PCR involves polymerization of nucleotide precursors using two oligonucleotide primers and an amplification enzyme, as well as the presence of metal ions. Mass spectrometric analysis greatly benefits from removal of the oligonucleotide primers (15- and 17-mers in this instance) and nucleotide precursors since they adversely affect sensitivity and metal ion adduction results in an inaccurate molecular weight determination. In the presence of guanidinium hydrochloride, the PCR products bind preferentially to a silica resin, allowing removal of other components (i.e., dNTP's, primers, and salts). Further removal of metal ions was accomplished using a microdialysis device, allowing samples to be pumped through a hollow cellulose fiber with an external countercurrent flow of 2.5 mM ammonium acetate. Prior to injection into the mass spectrometer, the sample buffer was adjusted to 50 vol % acetonitrile, 25 mM piperidine, and 25 mM imidazole, which enhanced signal intensity. The molecular weights of the PCR products determined by nucleotide sequence and MS analysis were in excellent agreement, and several PCR products were analyzed where mass differences corresponding to single base substitutions could be accurately assigned. These assignments were possible due to the high mass precision, accuracy, and resolution FTICR inherently affords. This constitutes the first report demonstrating the ionization and detection of PCR products by mass spectrometry with mass precision and accuracy for assigment of such modifications or substitutions.Keywords
This publication has 26 references indexed in Scilit:
- “Colored” Noise Waveforms and Quadrupole Excitation for the Dynamic Range Expansion of Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 1996
- Applications of Delayed Extraction Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry to Oligonucleotide AnalysisAnalytical Chemistry, 1996
- Sequencing 50-mer DNAs Using Electrospray Tandem Mass Spectrometry and Complementary Fragmentation MethodsJournal of the American Chemical Society, 1995
- Selected ion accumulation of noncovalent complexes in a fourier transform ion cyclotron resonance mass spectrometerJournal of Mass Spectrometry, 1995
- Various factors influencing the signal intensity of oligonucleotides in electrospray mass spectrometryJournal of Mass Spectrometry, 1994
- Rapid Sequencing of Oligonucleotides by High-Resolution Mass SpectrometryJournal of the American Chemical Society, 1994
- Decompositions of multiply charged oligonucleotide anionsJournal of the American Chemical Society, 1993
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Fidelity of DNA synthesis by the Thermus aquaticus DNA polymeraseBiochemistry, 1988
- Enzymatic Amplification of β-Globin Genomic Sequences and Restriction Site Analysis for Diagnosis of Sickle Cell AnemiaScience, 1985