The distribution of cartilage thickness within the joints of the lower limb of elderly individuals
Open Access
- 1 August 1998
- journal article
- research article
- Published by Wiley in Journal of Anatomy
- Vol. 193 (2) , 203-214
- https://doi.org/10.1046/j.1469-7580.1998.19320203.x
Abstract
The objective of this study was to investigate the normal distribution of cartilage thickness in the major joints of the lower limb in elderly individuals. A 12.5 MHz ultrasound transducer was used to measure the cartilage thickness in the right and left hip, knee and ankle joint of 10 individuals aged between 62 and 99 y. Distribution patterns of cartilage thickness were derived by b-spline interpolation and the average distribution computed in each surface. The maximum cartilage thickness in the hip joint was 2.6 (+/-0.36) mm and the mean thickness 1.3 (+/-0.17) mm. The CV% (a measure of thickness inhomogeneity within the joint surface) was 32%. In the knee, the maximal and mean values were 3.8 (+/-0.46) mm and 1.9 mm (+/-0.24) mm, respectively (CV% = 34%), and in the ankle 1.7 (+/-0.25) mm and 1.0 (+/-0.16) mm (CV% = 32%). Systematic differences existed between both sides in the knee, the distal femur showing a significantly greater thickness on the right. While the mean and maximal thicknesses were systematically higher in the knee than in the hip, and in the hip higher than in the ankle (P < 0.05), there were no systematic differences in the thickness inhomogeneity of the 3 joints. Only the malleolus showed a somewhat more uniform thickness than the other joint surfaces. The variability between individuals was similar for all joints for mean thickness, but the interindividual variability of the maximal thickness values was highest in the knee and lowest in the ankle. Whereas the cartilage thickness distributions in the joints of the lower limb have been suggested to reflect the pressure distribution within the articular surface, the absolute thickness is proposed to be a function of dynamic loading (range of motion) during gait, rather than being a reflection of the static articular pressure.Keywords
This publication has 39 references indexed in Scilit:
- Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imagingJournal of Biomechanics, 1997
- Contact area and pressure load at the implant/bone interface of press-fit cups compared with natural hip jointsDer Orthopäde, 1997
- Articular cartilage thickness and glycosaminoglycan distribution in the young canine knee joint after remobilization of the immobilized limbJournal of Orthopaedic Research, 1994
- Articular contact in a three-dimensional model of the kneeJournal of Biomechanics, 1991
- Mechanical loading history and skeletal biologyJournal of Biomechanics, 1987
- In-Vitro of Measurement of Static Pressure Distribution in Synovial Joints—Part I: Tibial Surface of the KneeJournal of Biomechanical Engineering, 1983
- In-Vitro Measurement of Static Pressure Distribution in Synovial Joints—Part II: Retropatellar SurfaceJournal of Biomechanical Engineering, 1983
- Effect of age on thickness of adult patellar articular cartilage.Annals of the Rheumatic Diseases, 1977
- Thickness and distribution of human femoral head articular cartilage. Changes with age.Annals of the Rheumatic Diseases, 1977
- Gelenkmechanische Untersuchungen zum Problem der posttraumatischen Arthrosen im oberen Sprunggelenk II. Einfluß der Talusform auf die Biomechanik des oberen SprunggelenkesLangenbecks Archives Of Surgery, 1971