Real‐time accelerated interactive MRI with adaptive TSENSE and UNFOLD
Open Access
- 17 July 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (2) , 315-321
- https://doi.org/10.1002/mrm.10504
Abstract
Reduced field‐of‐view (FOV) acceleration using time‐adaptive sensitivity encoding (TSENSE) or unaliasing by Fourier encoding the overlaps using the temporal dimension (UNFOLD) can improve the depiction of motion in real‐time MRI. However, increased computational resources are required to maintain a high frame rate and low latency in image reconstruction and display. A high‐performance software system has been implemented to perform TSENSE and UNFOLD reconstructions for real‐time MRI with interactive, on‐line display. Images were displayed in the scanner room to investigate image‐guided procedures. Examples are shown for normal volunteers and cardiac interventional experiments in animals using a steady‐state free precession (SSFP) sequence. In order to maintain adequate image quality for interventional procedures, the imaging rate was limited to seven frames per second after an acceleration factor of 2 with a voxel size of 1.8 × 3.5 × 8 mm. Initial experiences suggest that TSENSE and UNFOLD can each improve the compromise between spatial and temporal resolution in real‐time imaging, and can function well in interactive imaging. UNFOLD places no additional constraints on receiver coils, and is therefore more flexible than SENSE methods; however, the temporal image filtering can blur motion and reduce the effective acceleration. Methods are proposed to overcome the challenges presented by the use of TSENSE in interactive imaging. TSENSE may be temporarily disabled after changing the imaging plane to avoid transient artifacts as the sensitivity coefficients adapt. For imaging with a combination of surface and interventional coils, a hybrid reconstruction approach is proposed whereby UNFOLD is used for the interventional coils, and TSENSE with or without UNFOLD is used for the surface coils. Magn Reson Med 50:315–321, 2003. Published 2003 Wiley‐Liss, Inc.Keywords
This publication has 20 references indexed in Scilit:
- Interventional MRA using actively visualized catheters, TrueFISP, and real‐time image fusionMagnetic Resonance in Medicine, 2002
- Real-Time Volume Rendered MRI for Interventional GuidanceJournal of Cardiovascular Magnetic Resonance, 2002
- Using UNFOLD to remove artifacts in parallel imaging and in partial‐Fourier imagingMagnetic Resonance in Medicine, 2002
- Catheter-based endomyocardial injection with real-time magnetic resonance imaging.Published by Wiley ,2002
- Self‐calibrating parallel imaging with automatic coil sensitivity extractionMagnetic Resonance in Medicine, 2002
- Multifunctional interventional devices for MRI: A combined electrophysiology/MRI catheterMagnetic Resonance in Medicine, 2002
- Multiple field of view MR fluoroscopyMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Real‐time acquisition, display, and interactive graphic control of NMR cardiac profiles and imagesMagnetic Resonance in Medicine, 1993
- Real-time MR fluoroscopic data acquisition and image reconstructionMagnetic Resonance in Medicine, 1989