Systolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension
- 1 December 1998
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 89 (6) , 1313-1321
- https://doi.org/10.1097/00000542-199812000-00007
Abstract
Background: Monitoring left ventricular preload is critical to achieve adequate fluid resuscitation in patients with hypotension and sepsis. This prospective study tested the correlation of the pulmonary artery occlusion pressure, the left ventricular end-diastolic area index measured by transesophageal echocardiography, the arterial systolic pressure variation (the difference between maximal and minimal systolic blood pressure values during one mechanical breath), and its delta down (dDown) component (= apneic - minimum systolic blood pressure) with the response of cardiac output to volume expansion during sepsis. Methods: Preload parameters were measured at baseline and during graded volume expansion (increments of 500 ml) in 15 patients with sepsis-induced hypotension who required mechanical ventilation. Each volume-loading step (VLS) was classified as a responder (increase in stroke volume index > or = 15%) or a nonresponder. Successive VLSs were performed until a nonresponder VLS was obtained. Results: Thirty-five VLSs (21 responders) were performed. Fluid loading caused an overall significant increase in pulmonary artery occlusion pressure and end-diastolic area index, and a significant decrease in systolic pressure variation and delta down (P < 0.01). There was a significant difference between responder and nonresponder VLSs in end-diastolic area index, systolic pressure variation, and dDown, but not in pulmonary artery occlusion pressure. Receiver-operator curve analysis showed that dDown was a more accurate indicator of the response of stroke volume index to volume loading than end-diastolic area index and pulmonary artery occlusion pressure. A dDown component of more than 5 mmHg indicated that the stroke volume index would increase in response to a subsequent fluid challenge (positive and negative predictive values: 95% and 93%, respectively). Conclusion: The dDown component of the systolic pressure variation is a sensitive indicator of the response of cardiac output to volume infusion in patient with sepsis-induced hypotension who require mechanical ventilation.Keywords
This publication has 16 references indexed in Scilit:
- Transesophageal EchocardiographyAnesthesia & Analgesia, 1996
- The Effect of Graded Hemorrhage and Intravascular Volume Replacement on Systolic Pressure Variation in Humans During Mechanical and Spontaneous VentilationAnesthesia & Analgesia, 1995
- Echocardiographic and Hemodynamic Indexes of Left Ventricular Preload in Patients with Normal and Abnormal Ventricular FunctionAnesthesiology, 1994
- A Comparison of Systolic Blood Pressure Variations and Echocardiographic Estimates of End-Diastolic Left Ventricular Size in Patients After Aortic SurgeryAnesthesia & Analgesia, 1994
- Pathogenetic Mechanisms of Septic ShockNew England Journal of Medicine, 1993
- The Arterial Pressure Waveform During Acute Ventricular Failure and Synchronized External Chest CompressionAnesthesia & Analgesia, 1989
- Systolic Pressure Variation Is Greater during Hemorrhage than during Sodium Nitroprusside-Induced Hypotension in Ventilated DogsAnesthesia & Analgesia, 1988
- A Comparison of Hemodynamic Indices Derived by Invasive Monitoring and Two-dimensional EchocardiographyAnesthesiology, 1987
- Systolic Blood Pressure Variation is a Sensitive Indicator of Hypovolemia in Ventilated Dogs Subjected to Graded HemorrhageAnesthesiology, 1987
- Optimum left heart filling pressure during fluid resuscitation of patients with hypovolemic and septic shockCritical Care Medicine, 1983