Comparison of electrical transients and corrosion responses of pulsed MP35N and 316LVM electrodes
- 1 March 1994
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 22 (2) , 202-211
- https://doi.org/10.1007/bf02390378
Abstract
Functional neuromuscular stimulation (FNS) is often limited by electrode malfunctions such as corrosion and breakage, particularly for intramuscular and epimysial type electrodes. As a result, the electrochemical charge injection characteristics and corrosion responses of single strand 316LVM stainless steel and MP35N nickel-cobalt alloy electrodes were evaluatedin vitro. For charge balance, capacitor coupled monophasic protocols with varying charge injections were employed. Electrodes were evaluated with either positive-first or negative-first pulses, 60 Hz, 100 μsec pulse duration, and stimulation periods from 100 to 240 hours. Charge injection densities ranged from 20 to 80 μC/cm2. For both anodic-first and cathodic-first pulsing, the potential transients for the MP35N electrodes were more extreme than for the 316LVM electrodes over the test period, and increased corrosion was apparent on the MP35N electrodes from both optical and scanning electron microscopy. Therefore, 316LVM, but not MP35N, may be suitable for FNS applications with charge injection densities less than 40 μC/cm2.Keywords
This publication has 22 references indexed in Scilit:
- The application of a modified neuroprosthetic hand system in a child with a C7 spinal cord injury. Case reportSpinal Cord, 1992
- Neural prosthetic interfaces with the nervous systemTrends in Neurosciences, 1989
- Development of percutaneous intramuscular electrode for multichannel FES systemIEEE Transactions on Biomedical Engineering, 1989
- Pitting Corrosion of High Strength Alloy Stimulation Electrodes under Dynamic ConditionsJournal of the Electrochemical Society, 1989
- Electrostimulation of the median nerve in tetraplegics by means of implanted stimulatorsSpinal Cord, 1983
- Sacral anterior root stimulators for bladder control in paraplegiaSpinal Cord, 1982
- Electrical stimulation with Pt electrodes. IV. Factors influencing Pt dissolution in inorganic salineBiomaterials, 1980
- Discussion of “The Comparative Crevice Corrosion Resistance of Co‐Cr Base Surgical Implant Alloys” [T. M. Devine and J. Wulff (pp. 1433–1437, Vol. 123, No. 10)]Journal of the Electrochemical Society, 1977
- The Comparative Crevice Corrosion Resistance of Co‐Cr Base Surgical Implant AlloysJournal of the Electrochemical Society, 1976
- Metallurgical Principles in NeurosurgeryJournal of Neurosurgery, 1969