Identification of canine coronary resistance and intramyocardial compliance on the basis of the waterfall model
- 1 September 1985
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 13 (5) , 385-404
- https://doi.org/10.1007/bf02407768
Abstract
This study was performed to elucidate the effects of cardiac contraction on coronary pressure-flow relations. On the basis of the waterfall mechanism, a lumped model of the coronary arterial system is presented consisting of a proximal (epicardial) compliance, a coronary resistance, and an intramyocardial compliance. A “back”-pressure, assumed to be proportional (constant k) to left ventricular pressure, impedes flow. From steady-state measurements of circumflex coronary artery flow and inflow pressure, together with left ventricular pressure, the values of the three model parameters and the constant k have been estimated. In the control condition proximal compliance is found to be 1.7×10−12 m4s2kg−1, intramyocardial compliance 110×10−12m4s2kg−1, and resistance 7.5×109kgm−4s−1. The proportionality constant k is close to unity. Effects of changes in left ventricular pressure and inflow pressure and the effect of vasoactive drugs on the parameters are also investigated. Changes in coronary resistance are always opposite to changes in intramyocardial compliance. Sensitivity analysis showed that epicardial compliance plays its major role during isovolumic contraction and relaxation; resistance plays a role throughout the cardiac cycle but is more important in diastole than in systole, whereas intramyocardial compliance plays a role in systole and in early diastole.This publication has 23 references indexed in Scilit:
- Coronary pressure-flow relations and the vascular waterfallCardiovascular Research, 1983
- Influence of autoregulation and capacitance on diastolic coronary artery pressure-flow relationships in the dog.Circulation Research, 1982
- Intramyocardial pressure and distribution of coronary blood flow during systole and diastole in the horseCardiovascular Research, 1982
- Diastolic-systolic coronary flow differences are caused by intramyocardial pump action in the anesthetized dog.Circulation Research, 1981
- Comments on flow through collapsible tubes at low Reynolds numbers.Circulation Research, 1981
- Calculation of coronary vascular resistanceCardiovascular Research, 1980
- Unsteady flow in a collapsible tube subjected to external pressure or body forcesJournal of Fluid Mechanics, 1979
- Inhibition of coronary blood flow by a vascular waterfall mechanism.Circulation Research, 1975
- Epicardial Coronary Artery Compliance in the DogCirculation Research, 1970
- Intramural Pressure in the Left Ventricle of the DogCardiovascular Research, 1969