Considerations in use of microspheres for flow measurements in anesthetized rat
- 1 January 1986
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 250 (1) , H137-H143
- https://doi.org/10.1152/ajpheart.1986.250.1.h137
Abstract
The results of single injections of different doses of microspheres (60,000, 100,000, and 375,000) demonstrated a significant reduction in measured heart and kidney blood flows as a function of the number of microspheres injected. Measured flow to other organs was unaffected by a single injection of these doses of microspheres. The injection of microspheres at a faster rate (0.8 ml/min microsphere injection; 1.0 ml/min flush) resulted in higher calculated heart flow when compared with the slow rate (0.2 ml/min microsphere injection; 0.25 ml/min flush). A significant decrease (approximately 21%) in measured blood flow to the right side of the brain that was observed in all the groups is due to the occlusion of the right carotid artery by the cannulation procedure. Intra-aortic injection of microspheres resulted in reduced measured brain blood flow when compared with intraventricular injections. Accurate and reliable heart and brain blood flows were not obtained with intra-aortic injection of microspheres. However, intra-aortic injection of microspheres does provide accurate and reliable flow measurements for more distal organs.This publication has 12 references indexed in Scilit:
- Blood flow to different skeletal muscle fiber types during contractionAmerican Journal of Physiology-Heart and Circulatory Physiology, 1983
- Relative error and variability in blood flow measurements with radiolabeled microspheresAmerican Journal of Physiology-Heart and Circulatory Physiology, 1982
- A method for using microspheres to measure muscle blood flow in exercising ratsJournal of Applied Physiology, 1982
- Importance of injection site for coronary blood flow determinations by microspheres in ratsAmerican Journal of Physiology-Heart and Circulatory Physiology, 1982
- An additional source of error in microsphere measurement of regional blood flowMicrovascular Research, 1981
- Reference sample microsphere method: cardiac output and blood flows in conscious ratAmerican Journal of Physiology-Heart and Circulatory Physiology, 1980
- Dextran as a radioactive microsphere suspending agent: severe hypotensive effect in ratAmerican Journal of Physiology-Heart and Circulatory Physiology, 1978
- Reference sample method for cardiac output and regional blood flow determinations in the ratJournal of Applied Physiology, 1976
- The Circulation of the Fetus in UteroCirculation Research, 1967
- 5‐Hydroxytryptamine and the anaphylactoid reaction in the ratThe Journal of Physiology, 1957