Determinants of Release Rate of Tetanus Vaccine from Polyester Microspheres
- 1 January 1993
- journal article
- Published by Springer Nature in Pharmaceutical Research
- Vol. 10 (7) , 945-953
- https://doi.org/10.1023/a:1018942118148
Abstract
Controlled-release formulations based on poly(lactic) (PLA) and poly(lactic/glycolic) acid (PLGA) microspheres containing tetanus vaccine were designed. The polymers forming the microspheres were L-PLA of different molecular weights and DL-PLGA, 50:50. These microspheres were prepared by two solvent elimination procedures, both using a double emulsion, and were characterized for size, morphology, and toxoid release kinetics. The influence of formulation variables such as polymer type, vaccine composition, and vaccine/polymer ratio was also investigated. Both techniques yielded microspheres with similar size, morphology, and release properties. Microsphere size was dependent on the type of polymer and the presence of the surfactant L-α-phosphatidylcholine, which led to a reduction in microsphere size. On the other hand, the release kinetics of encapsulated protein were affected by the polymer properties (ratio lactic/glycolic acid and molecular weight) as well as by the vaccine composition, vaccine loading, and microsphere size. Moreover, for some formulations, a decrease in microsphere size occurred simultaneously, with an increase in porosity leading to an augmentation of release rate. The changes in the PLA molecular weight during in vitro release studies indicated that release profiles of tetanus toxoid from these microspheres were only marginally influenced by polymer degradation. A significant fraction of protein (between 15 and 35%) was initially released by diffusion through water-filled channels. In contrast, the decrease in the PLGA molecular weight over the first 10 days of incubation suggested that erosion of the polymer matrix substantially affects protein release from these microspheres. Among all formulations developed, two differing in microsphere size, polymer hydrophobicity, and release profile were selected for in vivo administration to mice. Administration of both formulations resulted in tetanus neutralizing antibody levels that were higher than those obtained after administration of the fluid toxoid.Keywords
This publication has 14 references indexed in Scilit:
- Biodegradable microspheres as controlled-release tetanus toxoid delivery systemsVaccine, 1994
- Parameters affecting the immunogenicity of microencapsulated tetanus toxoidVaccine, 1992
- Controlled Delivery Systems for Proteins Based on Poly(Lactic/Glycolic Acid) MicrospheresPharmaceutical Research, 1991
- Lactic Acid Oligomer Microspheres Containing Hydrophilic DrugsJournal of Pharmaceutical Sciences, 1990
- Effect of the size and surface charge of polymer microspheres on their phagocytosis by macrophageBiomaterials, 1988
- Single-step immunization using a controlled release, biodegradable polymer with sustained adjuvant activityJournal of Immunological Methods, 1986
- Prolonged Controlled-Release of Nafarelin, a Luteinizing Hormone-Releasing Hormone Analogue, from Biodegradable Polymeric Implants: Influence of Composition and Molecular Weight of PolymerJournal of Pharmaceutical Sciences, 1986
- The titration of tetanus antitoxin IV. Studies on the sensitivity and reproducibility of the toxin neutralization testJournal of Biological Standardization, 1985
- A single-step immunization by sustained antigen releaseJournal of Immunological Methods, 1979
- Titrage in vivo des anticorps antidiphtériques et antitétaniques à plusieurs niveauxJournal of Biological Standardization, 1977