EHV Cables with Compressed SF6 Gas Insulation
- 1 January 1967
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. PAS-86 (1) , 60-66
- https://doi.org/10.1109/tpas.1967.291776
Abstract
An EHV power cable with compressed pure SF6 gas insulation was produced experimentally, and succeeded in the dielectric withstand test. The outside diameter of one phase of the cable was 14 inches. The conductor, composed of a metal pipe 4½ inches in diameter, was arranged at the center of the outer pipe, and supported by spacers placed at intervals of about 15 feet.Keywords
This publication has 4 references indexed in Scilit:
- Some economic aspects of extra-high-voltage underground cablesProceedings of the Institution of Electrical Engineers, 1965
- Impulse-strength measurements on compressed-gas insulation for extra-high-voltage power cablesProceedings of the Institution of Electrical Engineers, 1965
- The calculation of the temperature rise and load capability of cable systemsTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1957