Experimental determination of friction characteristics at the trabecular bone/porous‐coated metal interface in cementless implants
- 1 February 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (2) , 167-175
- https://doi.org/10.1002/jbm.820270205
Abstract
An apparatus was developed to measure loaddisplacement friction properties at the cancellous bone/porous-coated metal plate interface. Bone cubes were obtained from different proximal regions of four resurfaced cadaveric tibiae. Three different poroussurfaced metal plates (one fiber mesh and two bead) and a smooth-surfaced metal plate were used. In the presence of a constant normal contact pressure (0.10, 0.15, or 0.25 MPa), a variable tangential load up to the maximum resistance of the interface was applied and both relative normal and tangential displacements were recorded. Repetitive and fatigue loadings were also considered. Measured results show that the interface friction curve is highly nonlinear, exhibiting large relative tangential displacements in the range of 50–400 μm before the maximum load is reached. Relative displacements in the normal direction remain below 10 μm. The maximum resistance in friction is independent of the bone excision site, type of porous-surfaced metal plate, magnitude of normal load, placement of bone cubes on metal plates or vice versa, repetition of applied load, and conservation period of bone cubes in saline solution. The smoothsurfaced metal plate has significantly smaller friction resistance than porous-coated ones. The fatigue loading of up to 4000 cycles at 1 Hz, in the presence of 0.25 MPa contact pressure, slightly decrease the interface friction coefficient. Finally, the initial secant stiffness of the interface at 75% of the maximum resistance load is found to be larger for the bone cubes from the lateral and medial regions and for the metal plate with smooth surface. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 19 references indexed in Scilit:
- The mechanical properties of human tibial trabecular bone as a function of metaphyseal locationPublished by Elsevier ,2004
- Finite Element Stress Analysis of a Push-Out Test Part II: Free Interface With Nonlinear Friction PropertiesJournal of Biomechanical Engineering, 1992
- The effect of screw fixation on initial rigidity of tibial knee componentsJournal of Applied Biomaterials, 1991
- The Effect of Screws and Pegs on the Initial Fixation Stability of an Uncemented Unicondylar Knee ReplacementPublished by Wolters Kluwer Health ,1990
- Effects of Screws and a Sleeve on Initial Fixation in Uncemented Total Knee Tibial ComponentsPublished by Wolters Kluwer Health ,1990
- Analysis of the Pull-out Strength of Screws and Pegs Used to Secure Tibial Components Following Total Knee ArthroplastyPublished by Wolters Kluwer Health ,1989
- Connective Tissue and ImmobilizationPublished by Wolters Kluwer Health ,1987
- Total Joint Arthroplasty of the KneeClinical Orthopaedics and Related Research, 1985
- Preliminary Experience with a Total Knee Prosthesis with Porous Coating Used without CementPublished by Wolters Kluwer Health ,1983
- The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of BoneClinical Orthopaedics and Related Research, 1980