Analysis of ``Immersed'' Thermocouple Error
- 1 March 1961
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 32 (3) , 313-316
- https://doi.org/10.1063/1.1717351
Abstract
The error of an ``immersed'' thermocouple due to heat leaks through the thermocouple wires has been estimated by means of a simple model. The error is shown to decrease exponentially with quantity L1/l1, where L1 is the ``immersion'' depth of the thermocouple and l1 is a characteristic length depending on thermocouple parameters and the mode of heat transfer. It is shown that large errors generally arise if such a thermocouple is used in vacuum. Calculations for specific cases are given.Keywords
This publication has 1 reference indexed in Scilit: