Vectorcardiographic loop alignment and morphologic beat-to-beat variability
- 1 January 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 45 (12) , 1401-1413
- https://doi.org/10.1109/10.730434
Abstract
The measurement of subtle morphologic beat-to-beat variations in the electrocardiogram is complicated by the presence of respiration-induced movements of the heart. A statistical signal model is developed which accounts for such movements by means of scaling, rotation, and time synchronization of vector-cardiographic loops. The maximum-likelihood estimator of the parameters describing these three transformations is presented and is extended to the case of multiple loop alignment. The performance of the method is assessed by measuring morphologic variability before and after loop alignment. It is shown that the effects of respiration on morphologic variability can be considerably reduced by the new method. Measurements on morphologic variability were typically reduced by a factor of 0.53 after loop alignment. The results show also that beat-to-beat measurements are strongly dependent on the selected sampling rate and that a rate of 1 kHz is too low.Keywords
This publication has 16 references indexed in Scilit:
- Time domain variability of high resolution beat-to-beat recordings classified by neural networksPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- On the detection of QRS variations in the ECGIEEE Transactions on Biomedical Engineering, 1995
- Time-varying digital filtering of ECG baseline wanderMedical & Biological Engineering & Computing, 1993
- Electrocardiogram signal variance analysis in the diagnosis of coronary artery disease—A comparison with exercise stress test in an angiographically documented high prevalence populationClinical Cardiology, 1993
- Beat-to-beat electrocardiographic morphology variation in healed myocardial infarctionThe American Journal of Cardiology, 1991
- ECG baseline wander reduction using linear phase filtersComputers and Biomedical Research, 1986
- Body position, electrode level, and respiration effects on the Frank lead electrocardiogram.Circulation, 1976
- Characterization of an adaptive filter for the analysis of variable latency neuroelectric signalsMedical & Biological Engineering & Computing, 1967
- Influence of respiration on recording cardiac potentialsThe American Journal of Cardiology, 1967
- Analysis of the Normal and Abnormal Vectorcardiogram in Its Own Reference FrameCirculation, 1962