Subpectoral Implantation of ICD Generators: Long-Term Follow-Up
- 1 January 1995
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 18 (1) , 159-162
- https://doi.org/10.1111/j.1540-8159.1995.tb02496.x
Abstract
A nonthoracotomy surgical approach using an endocardial electrode and combined implantation of a subcutaneous patch and the implantable cardioverter defibrillator (ICD) generator in a subpectoral pocket has been described. We report the long-term follow-up results in patients undergoing implantation using this approach. The patient population consisted of 28 patients (22 men and 6 women) with a mean age of 59 +/- 12 years. The underlying heart disease consisted of coronary artery disease in 20 patients and dilated cardiomyopathy in 8 patients. Sustained ventricular tachycardia was the mode of presentation in 16 patients and sudden cardiac death in 12 patients. The mean left ventricular ejection fraction was 31% +/- 6%. The lead system consisted of an 8 French bipolar passive fixation rate sensing lead positioned at the right ventricular apex, an 11 French spring coil electrode positioned at the superior vena cava-right atrial junction (surface area 700 mm2), and submuscular placement of a large patch (surface area 28 cm2) on the anterolateral chest wall near the cardiac apex via a submammary incision. A defibrillation threshold of < or = 15 joules (J) was required for implantation. This criterion was not satisfied in five patients; thus, a limited thoracotomy was performed via the submammary incision, and the large patch was placed epicardially. The mean R wave amplitude was 12 +/- 3 mV, the mean pacing threshold was 1.0 +/- 0.5 V at 0.5 msec, and the mean defibrillation threshold was 12.6 +/- 3 J. ICD generators implanted were the Ventak-P in 17, PCD-7217 in 5, and the Cadence V-100 in 6 patients.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 18 references indexed in Scilit:
- Subpectoral implantation of cardioverter-defibrillator combined with a nonepicardial lead system: Preliminary experience with a novel approachThe American Journal of Cardiology, 1993
- Initial Experience with Transvenous Implantable Cardioverter Defibrillator Lead Systems: Operative Morbidity and MortalityPacing and Clinical Electrophysiology, 1993
- Defibrillation Thresholds and Perioperative Mortality Associated with Endocardial and Epicardial Defihrillation Lead SystemsPacing and Clinical Electrophysiology, 1993
- Exacerbation of ventricular arrhythmias during the postoperative period after implantation of an automatic defibrillatorJournal of the American College of Cardiology, 1991
- An effective and adaptable transvenous defibrillation system using the coronary sinus in humansJournal of the American College of Cardiology, 1990
- Efficacy of the automatic implantable cardioverter-defibrillator in prolonging survival in patients with severe underlying cardiac diseaseJournal of the American College of Cardiology, 1990
- The automatic implantable cardioverter defibrillator: Efficacy, complications and survival in patients with malignant ventricular arrhythmiasJournal of the American College of Cardiology, 1988
- The automatic implantable cardioverter-defibrillator. Clinical experience, complications, and follow-up in 25 patientsArchives of internal medicine (1960), 1988
- Implantation of a cardioverter/defibrillator without thoracotomy using a triple electrode systemPublished by American Medical Association (AMA) ,1988
- Termination of Malignant Ventricular Arrhythmias with an Implanted Automatic Defibrillator in Human BeingsNew England Journal of Medicine, 1980