Sequence of mitral valve motion and transmitral blood flow during manual cardiopulmonary resuscitation in dogs.
- 1 August 1987
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 76 (2) , 363-375
- https://doi.org/10.1161/01.cir.76.2.363
Abstract
According to the thoracic pump model of cardiopulmonary resuscitation (CPR), the heart serves as a passive conduit for blood flow from the pulmonary to the systemic vasculature, necessitating an open mitral valve and anterograde transmitral blood flow during chest compression. To assess the applicability of this model to manual CPR techniques, two-dimensional echocardiograms were recorded from the right chest wall and/or the esophagus in nine dogs (18 to 26 kg) during manual CPR. The aortic valve opened with chest compression and closed with release, while the pulmonary and tricuspid valve leaflets closed with compression and opened during release. The mitral valve remained open during ventilation alone and during abdominal compressions. With the onset of brief, high-velocity (high-impulse) chest compressions, the mitral valve closed rapidly and the left ventricle was deformed, whether compressions were applied to the sternum or the left mid-chest wall. The mitral valve reopened with release of each compression. Left atrial echocardiographic contrast injections confirmed the absence of anterograde transmitral blood flow during high-impulse compression and its presence during release. Failure of mitral leaflet approximation during chest compression was observed only when a very low-velocity, prolonged (low-impulse) compression technique was used, or when regions that did not directly overlie the heart were compressed. Consistent with these observations, simultaneous recordings of the left ventricular and left atrial pressures during high-impulse sternal compressions in five dogs (19 to 25 kg) demonstrated peak and mean left ventriculoatrial pressure gradients of 38.5 +/- 4.0 and 13.5 +/- 2.9 mm Hg, respectively, and these pressure gradients declined with less impulsive compressions. The observations made during all but low-impulse chest compressions are inconsistent with the thoracic pump model, and support direct cardiac compression as the primary mechanism of forward blood flow with more impulsive manual chest compression techniques.This publication has 25 references indexed in Scilit:
- Echocardiographic observations during cardiopulmonary resuscitationCritical Care Medicine, 1985
- Transesophageal two-dimensional echocardiography: Comparison of ultrasonic and anatomic sectionsThe American Journal of Cardiology, 1984
- DETERMINANTS OF DIRECT CARDIAC COMPRESSION DURING EXTERNAL CARDIAC MASSAGE IN INTACT DOGSCritical Care Medicine, 1982
- Clinical assessment of heart chamber size and valve motion during cardiopulmonary resuscitation by two-dimensional echocardiographyAmerican Heart Journal, 1981
- Visualization of cardiac valve motion in man during external chest compression using two-dimensional echocardiography. Implications regarding the mechanism of blood flow.Circulation, 1981
- Documentation of systemic perfusion in man and in an experimental modelCritical Care Medicine, 1980
- Importance of Prolonged Compression during Cardiopulmonary Resuscitation in ManNew England Journal of Medicine, 1977
- Intracardiac pressures during closed-chest cardiac massageJAMA, 1968
- HÆMODYNAMIC EFFECTS OF EXTERNAL CARDIAC COMPRESSIONThe Lancet, 1964
- THE EFFICIENCY OF CARDIAC MASSAGEThe Lancet, 1962