Individual plasma proteins detected on rough biomaterials by phase imaging AFM
- 28 June 2000
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 51 (3) , 307-315
- https://doi.org/10.1002/1097-4636(20000905)51:3<307::aid-jbm3>3.0.co;2-h
Abstract
In the past several years, atomic force microscopy (AFM) has provided topographic images of adsorbed plasma proteins in situ at unprecedented resolution. Imaging has been limited to adsorbed protein on relatively smooth model substrates such as mica, graphite, or self-assembled monolayers on which the small height of the protein can be observed from the background. The inherent roughness of biomaterial surfaces has prevented observation of adsorbed proteins in topographic images. We report imaging isolated fibrinogen molecules adsorbed on National Heart Lung and Blood Institute (NHLBI) reference materials polydimethylsiloxane and low-density polyethylene in situ using phase imaging AFM. Fibrinogen, a plasma protein important for blood coagulation and platelet aggregation, was adsorbed from dilute solution onto reference biomaterial surfaces at sub-monolayer coverage. Tapping mode AFM was used to image the samples. For polydimethylsiloxane, the lateral size of the surface features is much greater than the dimensions of proteins. This allowed adsorbed proteins to be observed in topographic images. The phase imaging signal of tapping mode AFM provides information on differences in material properties of the surface, and was used to distinguish individual protein molecules from the underlying polymer surface. On the low-density polyethylene surface, characteristic topographical features are of the same magnitude as the protein molecules, so that protein cannot be distinguished from the surface using topographic images. However, phase images were used to successfully locate and characterize the distribution of the protein. Phase imaging was not able to distinguish fibrinogen adsorbed onto expanded polytetrafluoroethylene. The utility and limitations of the phase imaging technique for characterizing protein adsorption to rough surfaces is discussed. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 51, 307–315, 2000.Keywords
This publication has 21 references indexed in Scilit:
- Imaging fibrinogen adsorbed on noble metal surfaces with scanning tunneling microscopy: correlation of images with electron spectroscopy for chemical analysis, secondary ion mass spectrometry, and radiolabeling studiesColloids and Surfaces B: Biointerfaces, 1996
- Scanning probe microscopy of biomolecules and polymeric biomaterialsJournal of Electron Spectroscopy and Related Phenomena, 1996
- The Conformation of Fibronectin on Self-Assembled Monolayers with Different Surface Composition: An FTIR/ATR StudyJournal of Colloid and Interface Science, 1994
- Measurement of protein adsorption kinetics by an in situ, “real-time,” solution depletion techniqueJournal of Colloid and Interface Science, 1992
- Interactions of von Willebrand factor on mica studied by atomic force microscopyJournal of Colloid and Interface Science, 1992
- Infrared spectroscopic studies of time-dependent changes in fibrinogen adsorbed to polyurethanesLangmuir, 1991
- Absolute quantities and equilibrium kinetics of macromolecular adsorption measured by fluorescence photobleaching in total internal reflectionJournal of Colloid and Interface Science, 1990
- T-cell-mediated association of peptide antigen and major histocompatibility complex protein detected by energy transfer in an evanescent wave-fieldNature, 1986
- Fibronectin adsorption detected by interfacial fluorescenceJournal of Colloid and Interface Science, 1985
- Total internal reflection fluorescence: a technique for examining interactions of macromolecules with solid surfacesJournal of Colloid and Interface Science, 1983