Improvement of quantification in SPECT studies by scatter and attenuation compensation
- 1 July 1989
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 15 (7) , 351-356
- https://doi.org/10.1007/bf00449223
Abstract
The filtered backprojection images obtained from classical SPECT studies are not adequate for evaluation of volumes or parameters of clinical interest. Noise, scattering, boundary accuracy and attenuation are the main problems of SPECT quantification. It is the aim of the following study to overcome these difficulties. The first step of all correction algorithm is the contour detection of the attenuation medium. A new procedure, previously described by the authors, accurately and automatically found the boundaries of the surrounding body. The Compton scattering climination is carried out by a modified version of Jaszczak's method. This alteration is essential to implement the iterative attenuation correction algorithm derived from Chang's method. Results obtained using computer simulation and real phantoms or clinical studies demonstrate the high improvement of contrast and count levels in the corrected slices. The process is fully automatic and the efficiency of the procedures allow fast processing of the daily SPECT examination.Keywords
This publication has 14 references indexed in Scilit:
- A fully automated contour detection algorithm the preliminary step for scatter and attenuation compensation in SPECTEuropean Journal of Nuclear Medicine and Molecular Imaging, 1988
- A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT)European Journal of Nuclear Medicine and Molecular Imaging, 1987
- INVERSE MONTE-CARLO AS A UNIFIED RECONSTRUCTION ALGORITHM FOR ECT1986
- DECONVOLUTION OF COMPTON SCATTER IN SPECT1985
- Subtraction of Compton-scattered photons in single-photon emission computerized tomography.1984
- IMPROVED SPECT QUANTIFICATION USING COMPENSATION FOR SCATTERED PHOTONS1984
- Preprocessing of Spect Data as a Precursor for Attenuation CorrectionPublished by Springer Nature ,1984
- Attenuation Correction in Gamma Emission Computed TomographyJournal of Computer Assisted Tomography, 1981
- Compensation of tissue absorption in emission tomographyIEEE Transactions on Acoustics, Speech, and Signal Processing, 1979
- Attenuation Coefficients of Various Body Tissues, Fluids, and Lesions at Photon Energies of 18 to 136 keVRadiology, 1975