Bead-Based Electrochemical Immunoassay for Bacteriophage MS2
- 20 April 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (10) , 2700-2707
- https://doi.org/10.1021/ac035503c
Abstract
Viruses are one of four classes of biothreat agents, and bacteriophage MS2 has been used as a simulant for biothreat viruses, such as smallpox. A paramagnetic bead-based electrochemical immunoassay has been developed for detecting bacteriophage MS2. The immunoassay sandwich was made by attaching a biotinylated rabbit anti-MS2 IgG to a streptavidin-coated bead, capturing the virus, and then attaching a rabbit anti-MS2 IgG-β-galactosidase conjugate to another site on the virus. β-Galactosidase converts p-aminophenyl galactopyranoside (PAPG) to p-aminophenol (PAP). PAPG is electroinactive at the potential at which PAP is oxidized to p-quinone imine (PQI), so the current resulting from the oxidation of PAP to PQI is directly proportional to the concentration of antigen in the sample. The immunoassay was detected with rotating disk electrode (RDE) amperometry and an interdigitated array (IDA) electrode. With an applied potential of +290 mV vs Ag/AgCl and a rotation rate of 3000 rpm, the detection limit was 200 ng/mL MS2 or 3.2 × 1010 viral particles/mL with RDE amperometry. A trench IDA electrode was incorporated into a poly(dimethyl siloxane) channel, within which beads were collected, incubated with PAPG, and PAP generation was detected. The two working electrodes were held at +290 and −300 mV vs Ag/AgCl, and electrochemical recycling of the PAP/PQI couple by the IDA electrode lowered the limit of detection to 90 ng/mL MS2, or 1.5 × 1010 MS2 particles/mL.Keywords
This publication has 21 references indexed in Scilit:
- Electrochemical immunoassay moving into the fast laneTrAC Trends in Analytical Chemistry, 2002
- Micromachined flow-through filter-chamber for chemical reactions on beadsSensors and Actuators B: Chemical, 2000
- Micro volume rotating disk electrode (RDE) amperometric detection for a bead-based immunoassayAnalytica Chimica Acta, 1999
- Rotating disk electrode amperometric detection for a bead-based immunoassayJournal of Electroanalytical Chemistry, 1999
- Electroanalysis with interdigitated array microelectrodesElectroanalysis, 1995
- Electrochemical enzyme immunoassay using sequential saturation technique in a 20-μl capillary: digoxin as a model analyteAnalytica Chimica Acta, 1994
- Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassayAnalytical Chemistry, 1993
- The three-dimensional structure of the bacterial virus MS2Nature, 1990
- Homogeneous Voltammetric Immunoassay: A Preliminary StudyAnalytical Letters, 1979
- Purification and properties of bacteriophage MS2 and of its ribonucleic acidJournal of Molecular Biology, 1963