Development and evaluation of a dual-pump microcomputer-based closed-loop arterial pressure control system
- 1 January 1989
- journal article
- conference paper
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 6 (1) , 31-35
- https://doi.org/10.1007/bf01723370
Abstract
Hypertension after cardiac surgery is common and is associated with increased morbidity. It is usually managed by the infusion of short acting vasodilators. The use of a closed-loop computer system to control the infusion of a vasodilator has been shown to compare favourably with manual control. We have developed a closed-loop system for the ATARI 1040ST microcomputer to control arterial pressure by the simultaneous infusion of two vasodilators. The control program is based on a proportional-integral-derivative algorithm which has been adapted to allow control of two IMED 929 infusion pumps from one RS-232 port. All communication between the user and computer is carried out with a ‘mouse’, thus increasing acceptability of the system to ward staff. Cardiovascular data are collected on-line from the patient monitor via a custom-built analogue to digital convertor. This system was used to study glyceryl trinitrate and sodium nitroprusside in 24 patients requiring vasodilators after cardiopulmonary bypass. The study showed that in 14 of the patients hypertension was controlled by GTN alone and 10 required supplementary SNP. We have demonstrated that this dual-pump automatic arterial pressure control system is a satisfactory and safe method of administering two vasodilators simultaneously. It is suitable for both routine clinical and research uses.This publication has 11 references indexed in Scilit:
- Microcomputer-controlled administration of vasodilators following cardiac surgery: Technical considerationsJournal of Cardiothoracic Anesthesia, 1989
- Automatic control of arterial pressure after cardiac surgery Evaluation of a microcomputer‐based control system using glyceryl trinitrate and sodium nitroprussideAnaesthesia, 1989
- EVALUATION OF CLOSED-LOOP CONTROL OF ARTERIAL PRESSURE AFTER CARDIOPULMONARY BYPASSBritish Journal of Anaesthesia, 1987
- Fundamentals of feedback control applied to microcomputer instrumentation designJournal of Clinical Monitoring and Computing, 1986
- Comparison of intravenous nitroglycerin and sodium nitroprusside for treatment of acute hypertension developing after coronary artery bypass surgery.Circulation, 1982
- Systemic arterial hypertension associated with cardiac surgeryThe American Journal of Cardiology, 1980
- Vasodilator therapy after cardiac surgery: a review of the efficacy and toxicity of nitroglycerin and nitroprussideCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1980
- Sodium NitroprussideInternational Anesthesiology Clinics, 1978
- Systemic hypertension associated with coronary artery bypass surgeryThe Journal of Thoracic and Cardiovascular Surgery, 1977
- Comparison between the effects of nitroprusside and nitroglycerin on ischemic injury during acute myocardial infarction.Circulation, 1976