Capillary and Venous Blood Glucose Measurements Using a Direct Glucose‐sensing Meter
- 1 November 1991
- journal article
- Published by Wiley in Diabetic Medicine
- Vol. 8 (9) , 875-880
- https://doi.org/10.1111/j.1464-5491.1991.tb02128.x
Abstract
The aim of the study was to evaluate the precision and accuracy of the ExacTech home blood glucose meter when used with either capillary or venous blood and to compare this with a reference whole blood glucose assay. Non‐fasting glucose measurements were used since a validation study showed no capillary‐venous differences between fasting and postprandial states. In a cross‐sectional study, blood was taken from 182 patients and measured in duplicate on three batches of strips. Altogether we analysed 1089 readings. The regression of the data from capillary blood samples (meter vs reference method) had a correlation coefficient of 0.93, and a mean bias of 0.2 mmol l‐1. The corrected 90% confidence interval was ± 1.5 mmol l‐1 overall, and ± 0.9 mmol l‐1 for readings under 7.0 mmol l‐1. Regression of the data from venous blood samples (meter vs reference method) had a correlation coefficient of 0.93 and a slope of x 1.1. The corrected 90% confidence interval was ± 1.7 mmol l‐1. Thus venous blood may be used even though the meter is calibrated for capillary samples but the value must be corrected by dividing by 1.1. Error‐grid analysis showed that day‐to‐day clinical decisions could be made on the basis of ExacTech readings, although a diagnosis of borderline diabetes may not be possible.Keywords
This publication has 13 references indexed in Scilit:
- What Do Statistics Really Tell Us About the Quality of the Data from Self-Monitoring of Blood Glucose?Diabetic Medicine, 1989
- Patient evaluation of a pen-sized glucose meterPractical Diabetes International, 1988
- PEN-SIZED DIGITAL 30-SECOND BLOOD GLUCOSE METERThe Lancet, 1987
- Behavioral Skills in Self-Monitoring of Blood Glucose: Relationship to AccuracyDiabetes Care, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Accuracy of Perceiving Blood Glucose in IDDMDiabetes Care, 1985
- Unscientific and Opinionated Report on MetersThe Diabetes Educator, 1984
- Comparative Study of Home Blood Glucose Monitoring Devices: Visidex, Chemstrip bG, Glucometer, and Accu-Chek bGDiabetes Care, 1983
- Self Glucose Monitoring: A Comparison of the GLucometer, Glucoscan, and Hypocount BDiabetes Care, 1983
- Blood glucose monitors: a laboratory and patient assessment.BMJ, 1980