Quantitative analysis of vascular morphology from 3D MR angiograms: In vitro and in vivo results
Open Access
- 26 January 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 45 (2) , 311-322
- https://doi.org/10.1002/1522-2594(200102)45:2<311::aid-mrm1040>3.0.co;2-7
Abstract
A 3D model‐based approach for quantification of vascular morphology from several MRA acquisition protocols was evaluated. Accuracy, reproducibility, and influence of the image acquisition techniques were studied via in vitro experiments with ground truth diameters and the measurements of two expert readers as reference. The performance of the method was similar to or more accurate than the manual assessments and reproducibility was also improved. The methodology was applied to stenosis grading of carotid arteries from CE MRA data. In 11 patients, the approach was compared to manual scores (NASCET criterion) on CE MRA and DSA images, with the result that the model‐based technique correlates better with DSA than the manual scores. Spearman's correlation coefficient was 0.91 (P < 0.001) for the model‐based technique and DSA vs. 0.80 and 0.84 (P < 0.001) between the manual scores and DSA. From the results it can be concluded that the approach is a promising objective technique to assess geometrical vascular parameters, including degree of stenosis. Magn Reson Med 45:311–322, 2001.Keywords
This publication has 31 references indexed in Scilit:
- Retrospective motion correction in digital subtraction angiography: a reviewIEEE Transactions on Medical Imaging, 1999
- Randomised trial of endarterectomy for recently symptomatic carotid stenosis: final results of the MRC European Carotid Surgery Trial (ECST)The Lancet, 1998
- A viewpoint determination system for stenosis diagnosis and quantification in coronary angiographic image acquisitionIEEE Transactions on Medical Imaging, 1998
- Flow volume changes in the major cerebral arteries before and after carotid endarterectomy: an MR angiography studyEuropean Journal of Vascular and Endovascular Surgery, 1997
- MRA Flow Quantification in Patients With a Symptomatic Internal Carotid Artery OcclusionStroke, 1997
- MR Angiography of Abdominal and Peripheral ArteriesActa Radiologica, 1996
- Evaluation of Time-of-Flight and Phase-Contrast MRA Sequences at 1.0 T for Diagnosis of Carotid Artery DiseaseActa Radiologica, 1996
- Arteriographic complications in the DSA era.Radiology, 1992
- North American Symptomatic Carotid Endarterectomy Trial. Methods, patient characteristics, and progress.Stroke, 1991
- Estimation of the diameter of and iodine concentration within blood vessels using digital radiography devicesMedical Physics, 1981