Control of massive cardiac haemorrhage by balloon catheter
- 1 May 1973
- Vol. 28 (3) , 399-400
- https://doi.org/10.1136/thx.28.3.399
Abstract
The use of a balloon catheter to achieve the control of haemorrhage from the chambers of the heart has not been described previously. A case is reported in which this method was used in an emergency situation. It has been tested successfully, as a planned procedure, during four closed mitral valvotomy operations.Keywords