Effects of recombinant activated factor VII on coagulation measured by thromboelastography in liver transplantation

Abstract
Besides the conventional laboratory tests, thromboelastography (TEG) is used to monitor hemostasis during liver transplantation. A previous pilot study suggested a beneficial effect of recombinant activated factor VII (rFVIIa) on transfusion requirements in liver transplantation. In the present study, we assess the effects of rFVIIa on coagulation variables and TEG. In six study patients, the prothrombin time (PT), the activated partial thromboplastin time (aPTT) and TEG variables [reaction time (r), kinetic time (k), or clot formation time, α angle (α), and maximal amplitude (MA)] were recorded before and after the administration of a bolus of 80 μg/kg rFVIIa. These patients were compared with six controls who did not receive rFVIIa. In contrast with the control group, a significant shortening of PT (P = 0.028) and aPTT (P = 0.028), r (P = 0.046) and k (P = 0.043) values, and a significant incline of the α angle (P = 0.028) were noticed after injection of rFVIIa, whereas MA increased not significantly (P = 0.075). rFVIIa rapidly improved coagulation variables in liver transplant patients including PT and aPTT. Of the TEG variables, r, k and α angle significantly improved, and MA showed a trend to increase. These data suggest that rFVIIa not only influences the speed of clot formation, but also the physical properties of the clot, which cannot be detected by routine coagulation tests.