Cyclodextrin‐modified monolithic columns for resolving dansyl amino acid enantiomers and positional isomers by capillary electrochromatography
- 31 July 2003
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 24 (15) , 2550-2558
- https://doi.org/10.1002/elps.200305403
Abstract
We describe β- and γ-cyclodextrins (β- and γ-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 μm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of β- or γ-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. γ-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. β-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0×104 theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of −300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-Enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.Keywords
This publication has 42 references indexed in Scilit:
- Capillary Electrochromatography on Monolithic Silica ColumnsAnalytical Sciences, 2002
- Chemically l-Phenylalaninamide-Modified Monolithic Silica Column Prepared by a Sol−Gel Process for Enantioseparation of Dansyl Amino Acids by Ligand Exchange-Capillary ElectrochromatographyAnalytical Chemistry, 2001
- Chiral Monolithic Columns for Enantioselective Capillary Electrochromatography Prepared by Copolymerization of a Monomer with Quinidine Functionality. 1. Optimization of Polymerization Conditions, Porous Properties, and Chemistry of the Stationary PhaseAnalytical Chemistry, 2000
- Chiral Monolithic Columns for Enantioselective Capillary Electrochromatography Prepared by Copolymerization of a Monomer with Quinidine Functionality. 2. Effect of Chromatographic Conditions on the Chiral SeparationsAnalytical Chemistry, 2000
- Enantiomer separation by capillary electrochromatography on a cyclodextrin-modified monolithElectrophoresis, 2000
- Continuous-Bed Columns Containing Sol-Gel Bonded Packing Materials for Capillary ElectrochromatographyJournal of High Resolution Chromatography, 2000
- Preparation and Characterization of Monolithic Porous Capillary Columns Loaded with Chromatographic ParticlesAnalytical Chemistry, 1998
- Enantiomer Separation by Electrochromatography in Open Tubular Columns Coated with Chirasil-DexJournal of Liquid Chromatography, 1993
- Enantiomer separation by electrochromatography on capillaries coated with chirasil‐dex. Dedicated to Professor Ernst Bayer on the occasion of his 65th birthdayJournal of High Resolution Chromatography, 1992
- Retention behavior and chiral recognition mechanism of several cyclodextrin-bonded stationary phases for dansyl amino acidsAnalytical Chemistry, 1990